CTM Lyng mTouch_One
Model | mTouch_One |
Vendor | CTM Lyng |
Description | mTouch One OP, touch thermostat |
Exposes | lock (state), climate (occupied_heating_setpoint, local_temperature, system_mode, preset), load, display_text, regulator_mode, mean_power, floor_temp, frost_guard, regulator_setpoint, air_temp, linkquality |
Picture |
Options
How to use device type specific configuration
thermostat_unit
: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius
,fahrenheit
Exposes
Lock
The current state of this lock is in the published state under the child_lock
property (value is LOCK
or UNLOCK
).
To control this lock publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"child_lock": "LOCK"}
or {"child_lock": "UNLOCK"}
.
It’s not possible to read (/get
) this value.
Climate
This climate device supports the following features: occupied_heating_setpoint
, local_temperature
, system_mode
, preset
.
occupied_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_heating_setpoint": VALUE}
whereVALUE
is the °C between5
and40
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_heating_setpoint": ""}
.local_temperature
: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature": ""}
.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,heat
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"system_mode": ""}
.preset
: Mode of this device (similar to system_mode). To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"preset": VALUE}
whereVALUE
is one of:off
,away
,sleep
,home
. Reading (/get
) this attribute is not possible.
Load (numeric)
Load in W when heating is on (between 0-3600 W). The thermostat uses the value as input to the mean_power calculation..
Value can be found in the published state on the load
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"load": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"load": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 3600
.
The unit of this value is W
.
Display_text (text)
Displayed text on thermostat display (zone). Max 19 characters.
Value can be found in the published state on the display_text
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"display_text": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"display_text": NEW_VALUE}
.
Regulator_mode (binary)
Device in regulator or thermostat mode..
Value can be found in the published state on the regulator_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"regulator_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"regulator_mode": NEW_VALUE}
.
If value equals regulator
regulator_mode is ON, if thermostat
OFF.
Mean_power (numeric)
Reports average power usage last 10 minutes.
Value can be found in the published state on the mean_power
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"mean_power": ""}
.
It’s not possible to write (/set
) this value.
The unit of this value is W
.
Floor_temp (numeric)
Current temperature measured from the floor sensor.
Value can be found in the published state on the floor_temp
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"floor_temp": ""}
.
It’s not possible to write (/set
) this value.
The unit of this value is °C
.
Frost_guard (binary)
When frost guard is ON, it is activated when the thermostat is switched OFF with the ON/OFF button.At the same time, the display will fade and the text “Frostsikring x °C” appears in the display and remains until the thermostat is switched on again..
Value can be found in the published state on the frost_guard
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"frost_guard": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"frost_guard": NEW_VALUE}
.
If value equals ON
frost_guard is ON, if OFF
OFF.
Regulator_setpoint (numeric)
Setpoint in %, use only when the thermostat is in regulator mode..
Value can be found in the published state on the regulator_setpoint
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"regulator_setpoint": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"regulator_setpoint": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 99
.
The unit of this value is %
.
Air_temp (numeric)
Current temperature measured from the air sensor.
Value can be found in the published state on the air_temp
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"air_temp": ""}
.
It’s not possible to write (/set
) this value.
The unit of this value is °C
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.