LiXee ZiPulses
Model | ZiPulses |
Vendor | LiXee |
Description | Lixee ZiPulses |
Exposes | voltage, temperature, multiplier, divisor, unitOfMeasure, energy, linkquality |
Picture |
Options
How to use device type specific configuration
-
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Voltage (numeric)
Voltage of the battery in millivolts.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is mV
.
Temperature (numeric)
Measured temperature value.
Value can be found in the published state on the temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Multiplier (numeric)
It is necessary to press the link button to update.
Value can be found in the published state on the multiplier
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"multiplier": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 1000
.
Divisor (numeric)
It is necessary to press the link button to update.
Value can be found in the published state on the divisor
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"divisor": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 1000
.
UnitOfMeasure (enum)
It is necessary to press the link button to update.
Value can be found in the published state on the unitOfMeasure
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"unitOfMeasure": NEW_VALUE}
.
The possible values are: kWh
, m3
, ft3
, ccf
, US gl
, IMP gl
, BTUs
, L (litre)
, kPA (jauge)
, kPA (absolu)
, kPA (absolu)
, sans unité
, MJ
, kVar
.
Energy (numeric)
Value can be found in the published state on the energy
property.
It’s not possible to read (/get
) or write (/set
) this value.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.