Zen Zen-01-W

   
Model Zen-01-W
Vendor Zen
Description Thermostat
Exposes climate (occupied_heating_setpoint, occupied_cooling_setpoint, local_temperature, system_mode, running_state, local_temperature_calibration, pi_heating_demand), linkquality
Picture Zen Zen-01-W

Options

How to use device type specific configuration

  • thermostat_unit: Controls the temperature unit of the thermostat (default celsius). The value must be one of celsius, fahrenheit

  • legacy: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must be true or false

Exposes

Climate

This climate device supports the following features: occupied_heating_setpoint, occupied_cooling_setpoint, local_temperature, system_mode, running_state, local_temperature_calibration, pi_heating_demand.

  • occupied_heating_setpoint: Temperature setpoint. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"occupied_heating_setpoint": VALUE} where VALUE is the °C between 10 and 30. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"occupied_heating_setpoint": ""}.
  • occupied_cooling_setpoint: Temperature setpoint. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"occupied_cooling_setpoint": VALUE} where VALUE is the °C between 10 and 31. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"occupied_cooling_setpoint": ""}.
  • pi_heating_demand: Position of the valve (= demanded heat) where 0% is fully closed and 100% is fully open. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"pi_heating_demand": VALUE} where VALUE is the % between 0 and 100. Reading (/get) this attribute is not possible.
  • local_temperature: Current temperature measured on the device (in °C). To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"local_temperature": ""}.
  • system_mode: Mode of this device. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"system_mode": VALUE} where VALUE is one of: off, auto, heat, cool. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"system_mode": ""}.
  • running_state: The current running state. Possible values are: idle, heat, cool. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"running_state": ""}.
  • local_temperature_calibration: Offset to be used in the local_temperature. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"local_temperature_calibration": VALUE}.To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"local_temperature": ""}.The minimal value is -12.8 and the maximum value is 12.7 with a step size of 0.1.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.