AUBESS ZXZIR-02
| Model | ZXZIR-02 |
| Vendor | AUBESS |
| Description | Universal smart IR remote control |
| Exposes | switch (state), learned_ir_code, ir_code_to_send, linkquality |
| Picture | ![]() |
Notes
Device can learn IR codes and send already known IR codes.
Control
By publishing to zigbee2mqtt/FRIENDLY_NAME/set various device attributes can control the device:
Switch to a learning mode
Request:
{
"learn_ir_code":"ON"
}
The command activates the orange light on the device. You have several seconds to take source IR remote, move it closer to the device and press a button. The learned IR code will be exposed as learned_ir_code.
Send already learned IR code
Request:
{
"ir_code_to_send": "<previously learned IR code>"
}
Exposes
Switch
The current state of this switch is in the published state under the learn_ir_code property (value is ON or OFF).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"learn_ir_code": "ON"}, {"learn_ir_code": "OFF"} or {"learn_ir_code": "undefined"}.
It’s not possible to read (/get) this value.
Learned_ir_code (text)
The IR code learned by device.
Value can be found in the published state on the learned_ir_code property.
It’s not possible to read (/get) or write (/set) this value.
Ir_code_to_send (text)
The IR code to send by device.
Value will not be published in the state.
It’s not possible to read (/get) this value.
To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"ir_code_to_send": NEW_VALUE}.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality property.
It’s not possible to read (/get) or write (/set) this value.
The minimal value is 0 and the maximum value is 255.
The unit of this value is lqi.