TuYa ZS-TYG3-SM-61Z

   
Model ZS-TYG3-SM-61Z
Vendor TuYa
Description Smart switch (4 gang + 2 scene) with backlight and neutral wire
Exposes switch (state), backlight_mode, countdown, power_on_behavior, linkquality
Picture TuYa ZS-TYG3-SM-61Z

Exposes

Switch

The current state of this switch is in the published state under the state property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "ON"}, {"state": "OFF"} or {"state": "TOGGLE"}. It’s not possible to read (/get) this value.

Switch (l1 endpoint)

The current state of this switch is in the published state under the state_l1 property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state_l1": "ON"}, {"state_l1": "OFF"} or {"state_l1": "TOGGLE"}. It’s not possible to read (/get) this value.

Switch (l2 endpoint)

The current state of this switch is in the published state under the state_l2 property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state_l2": "ON"}, {"state_l2": "OFF"} or {"state_l2": "TOGGLE"}. It’s not possible to read (/get) this value.

Switch (l3 endpoint)

The current state of this switch is in the published state under the state_l3 property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state_l3": "ON"}, {"state_l3": "OFF"} or {"state_l3": "TOGGLE"}. It’s not possible to read (/get) this value.

Switch (l4 endpoint)

The current state of this switch is in the published state under the state_l4 property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state_l4": "ON"}, {"state_l4": "OFF"} or {"state_l4": "TOGGLE"}. It’s not possible to read (/get) this value.

Switch (l5 endpoint)

The current state of this switch is in the published state under the state_l5 property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state_l5": "ON"}, {"state_l5": "OFF"} or {"state_l5": "TOGGLE"}. It’s not possible to read (/get) this value.

Switch (l6 endpoint)

The current state of this switch is in the published state under the state_l6 property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state_l6": "ON"}, {"state_l6": "OFF"} or {"state_l6": "TOGGLE"}. It’s not possible to read (/get) this value.

Backlight_mode (binary)

Mode of the backlight. Value can be found in the published state on the backlight_mode property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"backlight_mode": NEW_VALUE}. If value equals ON backlight_mode is ON, if OFF OFF.

Countdown (numeric, l1 endpoint)

Countdown to turn device off after a certain time. Value can be found in the published state on the countdown_l1 property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"countdown_l1": NEW_VALUE}. The minimal value is 0 and the maximum value is 43200. The unit of this value is s.

Countdown (numeric, l2 endpoint)

Countdown to turn device off after a certain time. Value can be found in the published state on the countdown_l2 property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"countdown_l2": NEW_VALUE}. The minimal value is 0 and the maximum value is 43200. The unit of this value is s.

Countdown (numeric, l3 endpoint)

Countdown to turn device off after a certain time. Value can be found in the published state on the countdown_l3 property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"countdown_l3": NEW_VALUE}. The minimal value is 0 and the maximum value is 43200. The unit of this value is s.

Countdown (numeric, l4 endpoint)

Countdown to turn device off after a certain time. Value can be found in the published state on the countdown_l4 property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"countdown_l4": NEW_VALUE}. The minimal value is 0 and the maximum value is 43200. The unit of this value is s.

Countdown (numeric, l5 endpoint)

Countdown to turn device off after a certain time. Value can be found in the published state on the countdown_l5 property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"countdown_l5": NEW_VALUE}. The minimal value is 0 and the maximum value is 43200. The unit of this value is s.

Countdown (numeric, l6 endpoint)

Countdown to turn device off after a certain time. Value can be found in the published state on the countdown_l6 property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"countdown_l6": NEW_VALUE}. The minimal value is 0 and the maximum value is 43200. The unit of this value is s.

Power_on_behavior (enum)

Controls the behavior when the device is powered on after power loss. Value can be found in the published state on the power_on_behavior property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"power_on_behavior": NEW_VALUE}. The possible values are: off, previous, on.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.