Develco ZHEMI101
Model | ZHEMI101 |
Vendor | Develco |
Description | Energy meter |
Exposes | power, energy, battery_low, pulse_configuration, interface_mode, current_summation, check_meter, linkquality |
Picture |
Options
How to use device type specific configuration
-
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Power (numeric)
Instantaneous measured power.
Value can be found in the published state on the power
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is W
.
Energy (numeric)
Sum of consumed energy.
Value can be found in the published state on the energy
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is kWh
.
Battery_low (binary)
Indicates if the battery of this device is almost empty.
Value can be found in the published state on the battery_low
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
battery_low is ON, if false
OFF.
Pulse_configuration (numeric)
Pulses per kwh. Default 1000 imp/kWh. Range 0 to 65535.
Value can be found in the published state on the pulse_configuration
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"pulse_configuration": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"pulse_configuration": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 65535
.
Interface_mode (enum)
Operating mode/probe.
Value can be found in the published state on the interface_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"interface_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"interface_mode": NEW_VALUE}
.
The possible values are: electricity
, gas
, water
, kamstrup-kmp
, linky
, IEC62056-21
, DSMR-2.3
, DSMR-4.0
.
Current_summation (numeric)
Current summation value sent to the display. e.g. 570 = 0,570 kWh.
Value will not be published in the state.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"current_summation": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 268435455
.
Check_meter (binary)
Is true if communication problem with meter is experienced.
Value can be found in the published state on the check_meter
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
check_meter is ON, if false
OFF.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.