Fantem ZB003-X
Model | ZB003-X |
Vendor | Fantem |
Description | 4 in 1 multi sensor |
Exposes | occupancy, tamper, illuminance_lux, illuminance, temperature, humidity, battery, voltage, battery2, illuminance_calibration, temperature_calibration, humidity_calibration, reporting_enable, reporting_time, led_enable, pir_enable, sensitivity, keep_time, linkquality |
Picture |
Notes
Setting device options
Setting options (e.g. illuminance_calibration
) is only possible when the device is powered via an USB cable.
Options
How to use device type specific configuration
-
illuminance_calibration
: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number. -
illuminance_lux_calibration
: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number. -
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Occupancy (binary)
Indicates whether the device detected occupancy.
Value can be found in the published state on the occupancy
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
occupancy is ON, if false
OFF.
Tamper (binary)
Indicates whether the device is tampered.
Value can be found in the published state on the tamper
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
tamper is ON, if false
OFF.
Illuminance_lux (numeric)
Measured illuminance in lux.
Value can be found in the published state on the illuminance_lux
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is lx
.
Illuminance (numeric)
Raw measured illuminance.
Value can be found in the published state on the illuminance
property.
It’s not possible to read (/get
) or write (/set
) this value.
Temperature (numeric)
Measured temperature value.
Value can be found in the published state on the temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity.
Value can be found in the published state on the humidity
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Voltage (numeric)
Voltage of the battery in millivolts.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is mV
.
Battery2 (numeric)
Remaining battery 2 in %.
Value can be found in the published state on the battery2
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Illuminance_calibration (numeric)
Illuminance calibration in lux.
Value can be found in the published state on the illuminance_calibration
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"illuminance_calibration": NEW_VALUE}
.
The minimal value is -20
and the maximum value is 20
.
Temperature_calibration (numeric)
Temperature calibration (-2.0…2.0).
Value can be found in the published state on the temperature_calibration
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_calibration": NEW_VALUE}
.
The minimal value is -2
and the maximum value is 2
.
Humidity_calibration (numeric)
Humidity calibration.
Value can be found in the published state on the humidity_calibration
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"humidity_calibration": NEW_VALUE}
.
The minimal value is -15
and the maximum value is 15
.
Reporting_enable (binary)
Enable reporting.
Value can be found in the published state on the reporting_enable
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"reporting_enable": NEW_VALUE}
.
If value equals true
reporting_enable is ON, if false
OFF.
Reporting_time (numeric)
Reporting interval in minutes.
Value can be found in the published state on the reporting_time
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"reporting_time": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 1440
.
Led_enable (binary)
Enable LED.
Value can be found in the published state on the led_enable
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"led_enable": NEW_VALUE}
.
If value equals true
led_enable is ON, if false
OFF.
Pir_enable (binary)
Enable PIR sensor.
Value can be found in the published state on the pir_enable
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"pir_enable": NEW_VALUE}
.
If value equals true
pir_enable is ON, if false
OFF.
Sensitivity (enum)
PIR sensor sensitivity.
Value can be found in the published state on the sensitivity
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"sensitivity": NEW_VALUE}
.
The possible values are: low
, medium
, high
.
Keep_time (enum)
PIR keep time in seconds.
Value can be found in the published state on the keep_time
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"keep_time": NEW_VALUE}
.
The possible values are: 0
, 30
, 60
, 120
, 240
, 480
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.