Xiaomi WSDCGQ12LM
Model | WSDCGQ12LM |
Vendor | Xiaomi |
Description | Aqara T1 temperature, humidity and pressure sensor |
Exposes | temperature, humidity, pressure, device_temperature, battery, voltage, power_outage_count, linkquality |
Picture |
Notes
Adapter firmware
In order for this device to work (fully), at least the following firmware is required on your adapter:
- CC2530/CC2531:
20211115
- CC1352/CC2652:
20211114
- CC2538:
20211222
- Conbee II:
0x26720700
Note that if you have already paired the device you will need to repair it after upgrading your adapter firmware.
Pairing
Press and hold the reset button on the device for +- 5 seconds (until the blue light starts blinking). After this the device will automatically join. If this doesn’t work, try with a single short button press.
Note: When you fail to pair a device, try replacing the battery, this could solve the problem.
Troubleshooting: device stops sending messages/disconnects from network
Since Xiaomi devices do not fully comply to the Zigbee standard, it sometimes happens that they disconnect from the network. Most of the times this happens because of the following reasons:
- Device has a weak signal, you can see the signal quality in the published messages as
linkquality
. A linkquality < 20 is considered weak. - Low battery voltage, this can even happen when the battery still appears full. Try a different battery.
- The device is connected through a router which cannot deal with Xiaomi devices. This is known to happen devices from: Centralite, General Electric, Iris, Ledvance, Legrand, OSRAM, Sylvania, SmartThings, Securifi. A possible solution is to connect the device directly to the central coordinator by pushing the reset button while being physically close to it.
More detailed information about this can be found here.
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
pressure_calibration
: Calibrates the pressure value (absolute offset), takes into effect on next report of device. The value must be a number. -
pressure_precision
: Number of digits after decimal point for pressure, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
device_temperature_calibration
: Calibrates the device_temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Temperature (numeric)
Measured temperature value.
Value can be found in the published state on the temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity.
Value can be found in the published state on the humidity
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Pressure (numeric)
The measured atmospheric pressure.
Value can be found in the published state on the pressure
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is hPa
.
Device_temperature (numeric)
Temperature of the device.
Value can be found in the published state on the device_temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Voltage (numeric)
Voltage of the battery in millivolts.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is mV
.
Power_outage_count (numeric)
Number of power outages.
Value can be found in the published state on the power_outage_count
property.
It’s not possible to read (/get
) or write (/set
) this value.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.