TuYa TS0601_switch
Model | TS0601_switch |
Vendor | TuYa |
Description | 1, 2, 3 or 4 gang switch |
Exposes | switch (state), linkquality |
Picture | |
White-label | Norklmes MKS-CM-W5, Somgoms ZSQB-SMB-ZB, Moes WS-EUB1-ZG, AVATTO ZGB-WS-EU |
Notes
Pairing
Press any button 5 times, after this, click the button one more and hold the button.
Exposes
Switch (l1 endpoint)
The current state of this switch is in the published state under the state_l1
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l1": "ON"}
, {"state_l1": "OFF"}
or {"state_l1": "TOGGLE"}
.
It’s not possible to read (/get
) this value.
Switch (l2 endpoint)
The current state of this switch is in the published state under the state_l2
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l2": "ON"}
, {"state_l2": "OFF"}
or {"state_l2": "TOGGLE"}
.
It’s not possible to read (/get
) this value.
Switch (l3 endpoint)
The current state of this switch is in the published state under the state_l3
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l3": "ON"}
, {"state_l3": "OFF"}
or {"state_l3": "TOGGLE"}
.
It’s not possible to read (/get
) this value.
Switch (l4 endpoint)
The current state of this switch is in the published state under the state_l4
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l4": "ON"}
, {"state_l4": "OFF"}
or {"state_l4": "TOGGLE"}
.
It’s not possible to read (/get
) this value.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.