TuYa TS0601_smart_air_house_keeper
Model | TS0601_smart_air_house_keeper |
Vendor | TuYa |
Description | Smart air house keeper |
Exposes | temperature, humidity, co2, voc, formaldehyd, pm25, linkquality |
Picture |
Options
How to use device type specific configuration
-
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number. -
co2_precision
: Number of digits after decimal point for co2, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
co2_calibration
: Calibrates the co2 value (absolute offset), takes into effect on next report of device. The value must be a number. -
voc_precision
: Number of digits after decimal point for voc, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
voc_calibration
: Calibrates the voc value (absolute offset), takes into effect on next report of device. The value must be a number. -
formaldehyd_precision
: Number of digits after decimal point for formaldehyd, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
formaldehyd_calibration
: Calibrates the formaldehyd value (absolute offset), takes into effect on next report of device. The value must be a number. -
pm25_precision
: Number of digits after decimal point for pm25, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
pm25_calibration
: Calibrates the pm25 value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Temperature (numeric)
Measured temperature value.
Value can be found in the published state on the temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity.
Value can be found in the published state on the humidity
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Co2 (numeric)
The measured CO2 (carbon dioxide) value.
Value can be found in the published state on the co2
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is ppm
.
Voc (numeric)
Measured VOC value.
Value can be found in the published state on the voc
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is ppm
.
Formaldehyd (numeric)
The measured formaldehyd value.
Value can be found in the published state on the formaldehyd
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is µg/m³
.
Pm25 (numeric)
Measured PM2.5 (particulate matter) concentration.
Value can be found in the published state on the pm25
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 999
.
The unit of this value is µg/m³
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.