Livolo TI0001-dimmer
Model | TI0001-dimmer |
Vendor | Livolo |
Description | Zigbee dimmer |
Exposes | light (state, brightness), linkquality |
Picture |
Notes
After pairing device will be shown as “TI0001” device. Need to manually trigger a re-configure of the device either using web-frontend of Zigbee2MQTT or using MQTT message right after pairing. In case of problems it’s recommended to remove device and than retry pairing and re-configuring device.
Important
These devices can only be used on channel 26. These devices are locked to the manufacturer’s network key (ext_pan_id). Your configuration file data/configuration.yaml must contain the following:
advanced:
ext_pan_id: [33,117,141,25,0,75,18,0]
channel: 26
Therefore these devices may not co-existence with other Zigbee devices. Maybe, you need to add a dedicated coordinator and create a new network for Livolo. If you decided to create a new network, you should specify another ‘pan_id’.
advanced:
pan_id: 6756
Exposes
Light
This light supports the following features: state
, brightness
.
state
: To control the state publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"state": "ON"}
,{"state": "OFF"}
or{"state": "TOGGLE"}
. To read the state send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"state": ""}
.brightness
: To control the brightness publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"brightness": VALUE}
whereVALUE
is a number between0
and254
. To read the brightness send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"brightness": ""}
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.