Sinopé TH1400ZB
Model | TH1400ZB |
Vendor | Sinopé |
Description | Zigbee low volt thermostat |
Exposes | climate (occupied_heating_setpoint, unoccupied_heating_setpoint, local_temperature, system_mode, pi_heating_demand, running_state), max_heat_setpoint_limit, min_heat_setpoint_limit, thermostat_occupancy, second_display_mode, thermostat_outdoor_temperature, outdoor_temperature_timeout, enable_outdoor_temperature, temperature_display_mode, time_format, backlight_auto_dim, keypad_lockout, connected_load, floor_control_mode, floor_max_heat_setpoint, floor_min_heat_setpoint, ambiant_max_heat_setpoint, floor_temperature_sensor, main_cycle_output, aux_cycle_output, pump_protection, aux_connected_load, linkquality |
Picture |
Notes
Setting outdoor temperature
To set the outdoor temperature (value below the Out label on the thermostat display), you need to send the value to the following MQTT topic:
zigbee2mqtt/<FRIENDLY_NAME>/set/thermostat_outdoor_temperature
If you want to automate the publishing of the outdoor temperature using Home Assistant, you may create an automation like this:
- id: 'Auto_Publish_Outdoor_Temprature'
alias: 'Publish outside temperature'
description: 'Automatically Publish the outdoor temperature to thermostats'
mode: single
trigger:
- platform: state
entity_id: sensor.<OUTDOOR_TEMPERATURE_SENSOR_NAME>
condition: []
action:
- service: mqtt.publish
data:
topic: zigbee2mqtt/<FRIENDLY_NAME>/set/thermostat_outdoor_temperature
payload_template: ""
Setting outdoor temperature
To enable time you need to send a blank message to the following MQTT topic:
zigbee2mqtt/<FRIENDLY_NAME>/set/thermostat_time
Every time the above message is sent, Zigbee2MQTT will calculate the current time and send it to the thermostat.
If the thermostat loses power, you need to do this again. For Home Assistant users: if you want to avoid remembering to do this, you can
add the following action
to your Auto_Publish_Outdoor_Temperature
automation (noted above).
- service: mqtt.publish
data:
topic: zigbee2mqtt/<FRIENDLY_NAME>/set/thermostat_time
payload: ''
Options
How to use device type specific configuration
-
thermostat_unit
: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius
,fahrenheit
-
legacy
: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must betrue
orfalse
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number. -
current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number. -
voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
Exposes
Climate
This climate device supports the following features: occupied_heating_setpoint
, unoccupied_heating_setpoint
, local_temperature
, system_mode
, pi_heating_demand
, running_state
.
occupied_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_heating_setpoint": VALUE}
whereVALUE
is the °C between5
and36
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_heating_setpoint": ""}
.pi_heating_demand
: Position of the valve (= demanded heat) where 0% is fully closed and 100% is fully open. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"pi_heating_demand": VALUE}
whereVALUE
is the % between0
and100
. Reading (/get
) this attribute is not possible.local_temperature
: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature": ""}
.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,heat
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"system_mode": ""}
.running_state
: The current running state. Possible values are:idle
,heat
. Reading (/get
) this attribute is not possible.
Max_heat_setpoint_limit (numeric)
Maximum Heating set point limit.
Value can be found in the published state on the max_heat_setpoint_limit
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"max_heat_setpoint_limit": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_heat_setpoint_limit": NEW_VALUE}
.
The minimal value is 5
and the maximum value is 36
.
The unit of this value is °C
.
Min_heat_setpoint_limit (numeric)
Minimum Heating set point limit.
Value can be found in the published state on the min_heat_setpoint_limit
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"min_heat_setpoint_limit": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"min_heat_setpoint_limit": NEW_VALUE}
.
The minimal value is 5
and the maximum value is 36
.
The unit of this value is °C
.
Thermostat_occupancy (enum)
Occupancy state of the thermostat.
Value can be found in the published state on the thermostat_occupancy
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"thermostat_occupancy": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"thermostat_occupancy": NEW_VALUE}
.
The possible values are: unoccupied
, occupied
.
Second_display_mode (enum)
Displays the outdoor temperature and then returns to the set point in “auto” mode, or clears in “outdoor temp” mode when expired..
Value can be found in the published state on the second_display_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"second_display_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"second_display_mode": NEW_VALUE}
.
The possible values are: auto
, setpoint
, outdoor temp
.
Thermostat_outdoor_temperature (numeric)
Outdoor temperature for the secondary display.
Value can be found in the published state on the thermostat_outdoor_temperature
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"thermostat_outdoor_temperature": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"thermostat_outdoor_temperature": NEW_VALUE}
.
The minimal value is -99.5
and the maximum value is 99.5
.
The unit of this value is °C
.
Outdoor_temperature_timeout (numeric)
Time in seconds after which the outdoor temperature is considered to have expired.
Value can be found in the published state on the outdoor_temperature_timeout
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"outdoor_temperature_timeout": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"outdoor_temperature_timeout": NEW_VALUE}
.
The minimal value is 30
and the maximum value is 64800
.
The unit of this value is Seconds
.
Besides the numeric values the following values are accepected: 15 min
, 30 min
, 1 hour
.
Enable_outdoor_temperature (binary)
DEPRECATED: Use second_display_mode or control via outdoor_temperature_timeout.
Value can be found in the published state on the enable_outdoor_temperature
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"enable_outdoor_temperature": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"enable_outdoor_temperature": NEW_VALUE}
.
If value equals ON
enable_outdoor_temperature is ON, if OFF
OFF.
Temperature_display_mode (enum)
The temperature format displayed on the thermostat screen.
Value can be found in the published state on the temperature_display_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature_display_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_display_mode": NEW_VALUE}
.
The possible values are: celsius
, fahrenheit
.
Time_format (enum)
The time format featured on the thermostat display.
Value can be found in the published state on the time_format
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"time_format": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"time_format": NEW_VALUE}
.
The possible values are: 24h
, 12h
.
Backlight_auto_dim (enum)
The display backlight behavior.
Value can be found in the published state on the backlight_auto_dim
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"backlight_auto_dim": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"backlight_auto_dim": NEW_VALUE}
.
The possible values are: on_demand
, sensing
.
Keypad_lockout (enum)
Enables or disables the device’s buttons.
Value can be found in the published state on the keypad_lockout
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"keypad_lockout": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"keypad_lockout": NEW_VALUE}
.
The possible values are: unlock
, lock1
.
Connected_load (numeric)
The power in watts of the electrical load connected to the device.
Value can be found in the published state on the connected_load
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"connected_load": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"connected_load": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 20000
.
The unit of this value is W
.
Floor_control_mode (enum)
Control mode using floor or ambient temperature.
Value can be found in the published state on the floor_control_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"floor_control_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"floor_control_mode": NEW_VALUE}
.
The possible values are: ambiant
, floor
.
Floor_max_heat_setpoint (numeric)
The maximum floor temperature limit of the floor when in ambient control mode.
Value can be found in the published state on the floor_max_heat_setpoint
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"floor_max_heat_setpoint": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"floor_max_heat_setpoint": NEW_VALUE}
.
The minimal value is 7
and the maximum value is 36
.
The unit of this value is °C
.
Besides the numeric values the following values are accepected: off
.
Floor_min_heat_setpoint (numeric)
The minimum floor temperature limit of the floor when in ambient control mode.
Value can be found in the published state on the floor_min_heat_setpoint
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"floor_min_heat_setpoint": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"floor_min_heat_setpoint": NEW_VALUE}
.
The minimal value is 5
and the maximum value is 34
.
The unit of this value is °C
.
Besides the numeric values the following values are accepected: off
.
Ambiant_max_heat_setpoint (numeric)
The maximum ambient temperature limit when in floor control mode.
Value can be found in the published state on the ambiant_max_heat_setpoint
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"ambiant_max_heat_setpoint": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"ambiant_max_heat_setpoint": NEW_VALUE}
.
The minimal value is 5
and the maximum value is 36
.
The unit of this value is °C
.
Besides the numeric values the following values are accepected: off
.
Floor_temperature_sensor (enum)
The floor sensor.
Value can be found in the published state on the floor_temperature_sensor
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"floor_temperature_sensor": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"floor_temperature_sensor": NEW_VALUE}
.
The possible values are: 10k
, 12k
.
Main_cycle_output (enum)
The length of the control cycle according to the type of load connected to the thermostats.
Value can be found in the published state on the main_cycle_output
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"main_cycle_output": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"main_cycle_output": NEW_VALUE}
.
The possible values are: 15_sec
, 5_min
, 10_min
, 15_min
, 20_min
, 30_min
.
Aux_cycle_output (enum)
The length of the control cycle according to the type of auxiliary load connected to the thermostats.
Value can be found in the published state on the aux_cycle_output
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"aux_cycle_output": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"aux_cycle_output": NEW_VALUE}
.
The possible values are: off
, 15_sec
, 5_min
, 10_min
, 15_min
, 20_min
, 30_min
.
Pump_protection (binary)
This function prevents the seizure of the pump.
Value can be found in the published state on the pump_protection
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"pump_protection": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"pump_protection": NEW_VALUE}
.
If value equals ON
pump_protection is ON, if OFF
OFF.
Aux_connected_load (numeric)
The power in watts of the heater connected to the auxiliary output of the thermostat.
Value can be found in the published state on the aux_connected_load
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"aux_connected_load": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"aux_connected_load": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 20000
.
The unit of this value is W
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.