Sinopé TH1123ZB
Model | TH1123ZB |
Vendor | Sinopé |
Description | Zigbee line volt thermostat |
Exposes | climate (occupied_heating_setpoint, unoccupied_heating_setpoint, local_temperature, system_mode, pi_heating_demand, running_state), thermostat_occupancy, second_display_mode, thermostat_outdoor_temperature, outdoor_temperature_timeout, enable_outdoor_temperature, temperature_display_mode, time_format, backlight_auto_dim, keypad_lockout, main_cycle_output, power, current, voltage, energy, linkquality |
Picture |
Notes
Setting outdoor temperature
To set outdoor temperature, you need to send the value to the following MQTT topic:
zigbee2mqtt/<FRIENDLY_NAME>/set/thermostat_outdoor_temperature
If you want to automate the publishing of the outdoor temperature using Home Assistant, you may create an automation like this:
- id: 'Auto_Publish_Outdoor_Temprature'
alias: Auto_Publish_Outdoor_Temprature
description: Automatically Publish the outdoor temperature to thermostats
trigger:
- entity_id: sensor.outdoor_temprature_sensor
platform: state
condition: []
action:
- data:
payload_template: ''
topic: zigbee2mqtt/<FRIENDLY_NAME>/set/thermostat_outdoor_temperature
service: mqtt.publish
Enabling time
To enable time you need to send a blank message to the following MQTT topic:
zigbee2mqtt/<FRIENDLY_NAME>/set/thermostat_time
Every time the above message is sent, Zigbee2MQTT will calculate the current time and send it to the thermostat.
Options
How to use device type specific configuration
-
thermostat_unit
: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius
,fahrenheit
-
legacy
: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must betrue
orfalse
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number. -
current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number. -
voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Climate
This climate device supports the following features: occupied_heating_setpoint
, unoccupied_heating_setpoint
, local_temperature
, system_mode
, pi_heating_demand
, running_state
.
occupied_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_heating_setpoint": VALUE}
whereVALUE
is the °C between5
and30
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_heating_setpoint": ""}
.pi_heating_demand
: Position of the valve (= demanded heat) where 0% is fully closed and 100% is fully open. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"pi_heating_demand": VALUE}
whereVALUE
is the % between0
and100
. Reading (/get
) this attribute is not possible.local_temperature
: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature": ""}
.system_mode
: Mode of the thermostat. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,heat
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"system_mode": ""}
.running_state
: The current running state. Possible values are:idle
,heat
. Reading (/get
) this attribute is not possible.
Thermostat_occupancy (enum)
Occupancy state of the thermostat.
Value can be found in the published state on the thermostat_occupancy
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"thermostat_occupancy": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"thermostat_occupancy": NEW_VALUE}
.
The possible values are: unoccupied
, occupied
.
Second_display_mode (enum)
Displays the outdoor temperature and then returns to the set point in “auto” mode, or clears in “outdoor temp” mode when expired..
Value can be found in the published state on the second_display_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"second_display_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"second_display_mode": NEW_VALUE}
.
The possible values are: auto
, setpoint
, outdoor temp
.
Thermostat_outdoor_temperature (numeric)
Outdoor temperature for the secondary display.
Value can be found in the published state on the thermostat_outdoor_temperature
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"thermostat_outdoor_temperature": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"thermostat_outdoor_temperature": NEW_VALUE}
.
The minimal value is -99.5
and the maximum value is 99.5
.
The unit of this value is °C
.
Outdoor_temperature_timeout (numeric)
Time in seconds after which the outdoor temperature is considered to have expired.
Value can be found in the published state on the outdoor_temperature_timeout
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"outdoor_temperature_timeout": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"outdoor_temperature_timeout": NEW_VALUE}
.
The minimal value is 30
and the maximum value is 64800
.
The unit of this value is Seconds
.
Besides the numeric values the following values are accepected: 15 min
, 30 min
, 1 hour
.
Enable_outdoor_temperature (binary)
DEPRECATED: Use second_display_mode or control via outdoor_temperature_timeout.
Value can be found in the published state on the enable_outdoor_temperature
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"enable_outdoor_temperature": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"enable_outdoor_temperature": NEW_VALUE}
.
If value equals ON
enable_outdoor_temperature is ON, if OFF
OFF.
Temperature_display_mode (enum)
The temperature format displayed on the thermostat screen.
Value can be found in the published state on the temperature_display_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature_display_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_display_mode": NEW_VALUE}
.
The possible values are: celsius
, fahrenheit
.
Time_format (enum)
The time format featured on the thermostat display.
Value can be found in the published state on the time_format
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"time_format": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"time_format": NEW_VALUE}
.
The possible values are: 24h
, 12h
.
Backlight_auto_dim (enum)
Control backlight dimming behavior.
Value can be found in the published state on the backlight_auto_dim
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"backlight_auto_dim": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"backlight_auto_dim": NEW_VALUE}
.
The possible values are: on_demand
, sensing
.
Keypad_lockout (enum)
Enables or disables the device’s buttons.
Value can be found in the published state on the keypad_lockout
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"keypad_lockout": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"keypad_lockout": NEW_VALUE}
.
The possible values are: unlock
, lock1
.
Main_cycle_output (enum)
The length of the control cycle: 15_sec=normal 15_min=fan.
Value can be found in the published state on the main_cycle_output
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"main_cycle_output": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"main_cycle_output": NEW_VALUE}
.
The possible values are: 15_sec
, 15_min
.
Power (numeric)
Instantaneous measured power.
Value can be found in the published state on the power
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power": ""}
.
It’s not possible to write (/set
) this value.
The unit of this value is W
.
Current (numeric)
Instantaneous measured electrical current.
Value can be found in the published state on the current
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is A
.
Voltage (numeric)
Measured electrical potential value.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is V
.
Energy (numeric)
Sum of consumed energy.
Value can be found in the published state on the energy
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is kWh
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.