Sercomm SZ-PIR04N

   
Model SZ-PIR04N
Vendor Sercomm
Description PIR motion & temperature sensor
Exposes occupancy, tamper, illuminance, temperature, battery, voltage, linkquality
Picture Sercomm SZ-PIR04N

Options

How to use device type specific configuration

  • illuminance_calibration: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.

  • illuminance_lux_calibration: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number.

  • temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.

Exposes

Occupancy (binary)

Indicates whether the device detected occupancy. Value can be found in the published state on the occupancy property. It’s not possible to read (/get) or write (/set) this value. If value equals true occupancy is ON, if false OFF.

Tamper (binary)

Indicates whether the device is tampered. Value can be found in the published state on the tamper property. It’s not possible to read (/get) or write (/set) this value. If value equals true tamper is ON, if false OFF.

Illuminance (numeric)

Raw measured illuminance. Value can be found in the published state on the illuminance property. It’s not possible to read (/get) or write (/set) this value.

Temperature (numeric)

Measured temperature value. Value can be found in the published state on the temperature property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is °C.

Battery (numeric)

Remaining battery in %, can take up to 24 hours before reported.. Value can be found in the published state on the battery property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Voltage (numeric)

Voltage of the battery in millivolts. Value can be found in the published state on the voltage property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is mV.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.