Keen Home SV02
Model | SV02 |
Vendor | Keen Home |
Description | Smart vent |
Exposes | cover (state, position), temperature, battery, pressure, linkquality |
Picture |
Options
How to use device type specific configuration
-
invert_cover
: Inverts the cover position, false: open=100,close=0, true: open=0,close=100 (default false). The value must betrue
orfalse
-
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
pressure_precision
: Number of digits after decimal point for pressure, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
pressure_calibration
: Calibrates the pressure value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Cover
The current state of this cover is in the published state under the state
property (value is OPEN
or CLOSE
).
To control this cover publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "OPEN"}
, {"state": "CLOSE"}
, {"state": "STOP"}
.
To read the current state of this cover publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
To change the position publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"position": VALUE}
where VALUE
is a number between 0
and 100
.
Temperature (numeric)
Measured temperature value.
Value can be found in the published state on the temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Pressure (numeric)
The measured atmospheric pressure.
Value can be found in the published state on the pressure
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is hPa
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.