Xiaomi SSM-U02
Model | SSM-U02 |
Vendor | Xiaomi |
Description | Aqara single switch module T1 (without neutral). Doesn’t work as a router and doesn’t support power meter |
Exposes | switch (state), power_outage_memory, switch_type, power_outage_count, device_temperature, linkquality |
Picture |
Options
How to use device type specific configuration
-
state_action
: State actions will also be published as ‘action’ when true (default false). The value must betrue
orfalse
-
device_temperature_calibration
: Calibrates the device_temperature value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
Power_outage_memory (binary)
Enable/disable the power outage memory, this recovers the on/off mode after power failure.
Value can be found in the published state on the power_outage_memory
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_outage_memory": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_outage_memory": NEW_VALUE}
.
If value equals true
power_outage_memory is ON, if false
OFF.
Switch_type (enum)
Wall switch type.
Value can be found in the published state on the switch_type
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"switch_type": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"switch_type": NEW_VALUE}
.
The possible values are: toggle
, momentary
.
Power_outage_count (numeric)
Number of power outages (since last pairing).
Value can be found in the published state on the power_outage_count
property.
It’s not possible to read (/get
) or write (/set
) this value.
Device_temperature (numeric)
Temperature of the device.
Value can be found in the published state on the device_temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.