Climax SRAC-23B-ZBSR
Model | SRAC-23B-ZBSR |
Vendor | Climax |
Description | Smart siren |
Exposes | battery_low, tamper, warning, squawk, max_duration, alarm, linkquality |
Picture |
Notes
Warning usage
Warning only support a single mode, burglar
Duration of using warning
can be shorter than max_duration
but not longer. If max_duration
are set to 60 seconds, and you try to set warning
with duration
of 90 seconds, the warning will only apply for 60 seconds. Default value of max_duration
are 300 seconds
This device do not support the strobe_duty_cycle
functionality
Triggering alarm, Advanced
This siren can be triggered manually by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with the payloads:
To start :
{"warning":{"duration":60,"level":"low","mode":"burglar","strobe":false,"strobe_duty_cycle":0}}
Where:duration
: the number of seconds the alarm will be onlevel
:low
,medium
,high
,very_high
mode
:stop
,burglar
strobe
:true
,false
strobe_duty_cycle
: not supported
To stop:
{"warning":{"duration":60,"level":"low","mode":"stop","strobe":false,"strobe_duty_cycle":0}}
Triggering alarm, Simple
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"alarm": "START"}
and {"alarm": "OFF"}
Set max_duration
from the Zigbee2MQTT UI or by publishing {"max_duration": NEW_VALUE}
This alarm are preset to highest volume
Exposes
Battery_low (binary)
Indicates if the battery of this device is almost empty.
Value can be found in the published state on the battery_low
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
battery_low is ON, if false
OFF.
Tamper (binary)
Indicates whether the device is tampered.
Value can be found in the published state on the tamper
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
tamper is ON, if false
OFF.
Warning (composite)
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"warning": {"mode": VALUE, "level": VALUE, "strobe_level": VALUE, "strobe": VALUE, "strobe_duty_cycle": VALUE, "duration": VALUE}}
mode
(enum): Mode of the warning (sound effect) allowed values:stop
,burglar
,fire
,emergency
,police_panic
,fire_panic
,emergency_panic
level
(enum): Sound level allowed values:low
,medium
,high
,very_high
strobe_level
(enum): Intensity of the strobe allowed values:low
,medium
,high
,very_high
strobe
(binary): Turn on/off the strobe (light) during warning allowed values:true
orfalse
strobe_duty_cycle
(numeric): Length of the flash cycle max value is 10duration
(numeric): Duration in seconds of the alarm unit is s
Squawk (composite)
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"squawk": {"state": VALUE, "level": VALUE, "strobe": VALUE}}
state
(enum): Set Squawk state allowed values:system_is_armed
,system_is_disarmed
level
(enum): Sound level allowed values:low
,medium
,high
,very_high
strobe
(binary): Turn on/off the strobe (light) for Squawk allowed values:true
orfalse
Max_duration (numeric)
Duration of Siren.
Value can be found in the published state on the max_duration
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"max_duration": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_duration": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 600
.
The unit of this value is s
.
Alarm (binary)
Manual start of siren.
Value will not be published in the state.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"alarm": NEW_VALUE}
.
If value equals START
alarm is ON, if OFF
OFF.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.