Mercator Ikuü SPP02GIP

   
Model SPP02GIP
Vendor Mercator Ikuü
Description Double power point IP54
Exposes switch (state), power, current, voltage, energy, linkquality
Picture Mercator Ikuü SPP02GIP

Options

How to use device type specific configuration

  • state_action: State actions will also be published as ‘action’ when true (default false). The value must be true or false

  • power_calibration: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.

  • power_precision: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • current_calibration: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number.

  • current_precision: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • voltage_calibration: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number.

  • voltage_precision: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • energy_precision: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • energy_calibration: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.

Exposes

Switch (left endpoint)

The current state of this switch is in the published state under the state_left property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state_left": "ON"}, {"state_left": "OFF"} or {"state_left": "TOGGLE"}. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state_left": ""}.

Switch (right endpoint)

The current state of this switch is in the published state under the state_right property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state_right": "ON"}, {"state_right": "OFF"} or {"state_right": "TOGGLE"}. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state_right": ""}.

Power (numeric, left endpoint)

Instantaneous measured power. Value can be found in the published state on the power_left property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is W.

Current (numeric, left endpoint)

Instantaneous measured electrical current. Value can be found in the published state on the current_left property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is A.

Voltage (numeric, left endpoint)

Measured electrical potential value. Value can be found in the published state on the voltage_left property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is V.

Energy (numeric)

Sum of consumed energy. Value can be found in the published state on the energy property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is kWh.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.