Model | SPM01 |
Vendor | TuYa |
Description | Smart energy monitor for 1P+N system |
Exposes | voltage, power, current, energy, produced_energy, linkquality |
Picture |
Options
How to use device type specific configuration
-
energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number. -
voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number. -
current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number. -
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Voltage (numeric)
Measured electrical potential value.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is V
.
Power (numeric)
Instantaneous measured power.
Value can be found in the published state on the power
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is W
.
Current (numeric)
Instantaneous measured electrical current.
Value can be found in the published state on the current
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is A
.
Energy (numeric)
Total forward active energy.
Value can be found in the published state on the energy
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is kWh
.
Produced_energy (numeric)
Total reverse active energy.
Value can be found in the published state on the produced_energy
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is kWh
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.