Hive SLR2c
Model | SLR2c |
Vendor | Hive |
Description | Dual channel heating and hot water thermostat |
Exposes | climate (occupied_heating_setpoint, local_temperature, system_mode, running_state), temperature_setpoint_hold, temperature_setpoint_hold_duration, linkquality |
Picture |
Options
How to use device type specific configuration
thermostat_unit
: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius
,fahrenheit
Exposes
Climate (heat endpoint)
This climate device supports the following features: occupied_heating_setpoint
, local_temperature
, system_mode
, running_state
.
occupied_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_heating_setpoint_heat": VALUE}
whereVALUE
is the °C between5
and32
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_heating_setpoint_heat": ""}
.local_temperature
: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature_heat": ""}
.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode_heat": VALUE}
whereVALUE
is one of:off
,auto
,heat
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"system_mode_heat": ""}
.running_state
: The current running state. Possible values are:idle
,heat
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"running_state_heat": ""}
.
Temperature_setpoint_hold (binary, heat endpoint)
Prevent changes. false
= run normally. true
= prevent from making changes. Must be set to false
when system_mode = off or true
for heat.
Value can be found in the published state on the temperature_setpoint_hold_heat
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature_setpoint_hold_heat": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_setpoint_hold_heat": NEW_VALUE}
.
If value equals true
temperature_setpoint_hold is ON, if false
OFF.
Temperature_setpoint_hold_duration (numeric, heat endpoint)
Period in minutes for which the setpoint hold will be active. 65535 = attribute not used. 0 to 360 to match the remote display.
Value can be found in the published state on the temperature_setpoint_hold_duration_heat
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature_setpoint_hold_duration_heat": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_setpoint_hold_duration_heat": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 65535
.
Climate (water endpoint)
This climate device supports the following features: occupied_heating_setpoint
, local_temperature
, system_mode
, running_state
.
occupied_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_heating_setpoint_water": VALUE}
whereVALUE
is the °C between22
and22
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_heating_setpoint_water": ""}
.local_temperature
: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature_water": ""}
.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode_water": VALUE}
whereVALUE
is one of:off
,auto
,heat
,emergency_heating
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"system_mode_water": ""}
.running_state
: The current running state. Possible values are:idle
,heat
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"running_state_water": ""}
.
Temperature_setpoint_hold (binary, water endpoint)
Prevent changes. false
= run normally. true
= prevent from making changes. Must be set to false
when system_mode = off or true
for heat.
Value can be found in the published state on the temperature_setpoint_hold_water
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature_setpoint_hold_water": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_setpoint_hold_water": NEW_VALUE}
.
If value equals true
temperature_setpoint_hold is ON, if false
OFF.
Temperature_setpoint_hold_duration (numeric, water endpoint)
Period in minutes for which the setpoint hold will be active. 65535 = attribute not used. 0 to 360 to match the remote display.
Value can be found in the published state on the temperature_setpoint_hold_duration_water
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature_setpoint_hold_duration_water": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_setpoint_hold_duration_water": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 65535
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.