Develco SIRZB-110
Model | SIRZB-110 |
Vendor | Develco |
Description | Customizable siren |
Exposes | battery, battery_low, test, warning, squawk, max_duration, alarm, linkquality |
Picture |
Notes
Warning usage
Duration of using warning
can be shorter than max_duration
but not longer. If max_duration
are set to 60 seconds, and you try to set warning
with duration
of 90 seconds, the warning will only apply for 60 seconds. Default value of max_duration
are 900 seconds
This device do not support the strobe
and strobe_duty_cycle
functionality
Triggering the alarm, Advanced
This siren can be triggered manually by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with the payloads:
To start :
{"warning":{"duration":60,"level":"low","mode":"burglar","strobe":false,"strobe_duty_cycle":0}}
Where:duration
: the number of seconds the alarm will be onlevel
:low
,medium
,high
,very_high
mode
:stop
,burglar
,fire
,emergency
,police_panic
,fire_panic
,emergency_panic
strobe
: not supportedstrobe_duty_cycle
: not supported
To stop:
{"warning":{"duration":60,"level":"low","mode":"stop","strobe":false,"strobe_duty_cycle":0}}
Triggering alarm, Simple
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"alarm": "START"}
and {"alarm": "OFF"}
Set max_duration
from the Zigbee2MQTT UI or by publishing {"max_duration": NEW_VALUE}
This alarm are preset to highest volume and using the mode police_panic
Squawk
Squawk are normally used to indicate activation and deactivation of an alarm system
Examples:
{"squawk":{"level":"low","mode":"system_is_sarmed","strobe":false}}
{"squawk":{"level":"low","mode":"system_is_disarmed","strobe":false}}
Options
How to use device type specific configuration
-
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Battery_low (binary)
Indicates if the battery of this device is almost empty.
Value can be found in the published state on the battery_low
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
battery_low is ON, if false
OFF.
Test (binary)
Indicates whether the device is being tested.
Value can be found in the published state on the test
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
test is ON, if false
OFF.
Warning (composite)
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"warning": {"mode": VALUE, "level": VALUE, "strobe_level": VALUE, "strobe": VALUE, "strobe_duty_cycle": VALUE, "duration": VALUE}}
mode
(enum): Mode of the warning (sound effect) allowed values:stop
,burglar
,fire
,emergency
,police_panic
,fire_panic
,emergency_panic
level
(enum): Sound level allowed values:low
,medium
,high
,very_high
strobe_level
(enum): Intensity of the strobe allowed values:low
,medium
,high
,very_high
strobe
(binary): Turn on/off the strobe (light) during warning allowed values:true
orfalse
strobe_duty_cycle
(numeric): Length of the flash cycle max value is 10duration
(numeric): Duration in seconds of the alarm unit is s
Squawk (composite)
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"squawk": {"state": VALUE, "level": VALUE, "strobe": VALUE}}
state
(enum): Set Squawk state allowed values:system_is_armed
,system_is_disarmed
level
(enum): Sound level allowed values:low
,medium
,high
,very_high
strobe
(binary): Turn on/off the strobe (light) for Squawk allowed values:true
orfalse
Max_duration (numeric)
Max duration of the siren.
Value can be found in the published state on the max_duration
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"max_duration": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_duration": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 900
.
The unit of this value is s
.
Alarm (binary)
Manual start of the siren.
Value will not be published in the state.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"alarm": NEW_VALUE}
.
If value equals START
alarm is ON, if OFF
OFF.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.