Saswell SEA801-Zigbee/SEA802-Zigbee
Model | SEA801-Zigbee/SEA802-Zigbee |
Vendor | Saswell |
Description | Thermostatic radiator valve |
Exposes | battery_low, switch (state), lock (state), heating, climate (current_heating_setpoint, local_temperature, system_mode, local_temperature_calibration), linkquality |
Picture | |
White-label | HiHome WZB-TRVL, Hama 00176592, RTX ZB-RT1, SETTI+ TRV001 |
Notes
Pairing
- SEA801-Zigbee (LCD display on the front, several buttons): Long hold the “AUTO/MANU” and “+” Button until the LCD display shows “—-“
- SEA802-Z01 (white LED display on the side, rotary plate): Turn the rotary plate to decrease the temperature until the LED dots show “OF”, then long press until the display changes to “–”
Options
How to use device type specific configuration
legacy
: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must betrue
orfalse
Exposes
Battery_low (binary)
Indicates if the battery of this device is almost empty.
Value can be found in the published state on the battery_low
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
battery_low is ON, if false
OFF.
Switch
The current state of this switch is in the published state under the window_detection
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"window_detection": "ON"}
, {"window_detection": "OFF"}
or {"window_detection": "TOGGLE"}
.
It’s not possible to read (/get
) this value.
Lock
The current state of this lock is in the published state under the child_lock
property (value is LOCK
or UNLOCK
).
To control this lock publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"child_lock": "LOCK"}
or {"child_lock": "UNLOCK"}
.
It’s not possible to read (/get
) this value.
Switch
The current state of this switch is in the published state under the away_mode
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"away_mode": "ON"}
, {"away_mode": "OFF"}
or {"away_mode": "undefined"}
.
It’s not possible to read (/get
) this value.
Heating (binary)
Device valve is open or closed (heating or not).
Value can be found in the published state on the heating
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals ON
heating is ON, if OFF
OFF.
Climate
This climate device supports the following features: current_heating_setpoint
, local_temperature
, system_mode
, local_temperature_calibration
.
current_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"current_heating_setpoint": VALUE}
whereVALUE
is the °C between5
and30
. Reading (/get
) this attribute is not possible.local_temperature
: Current temperature measured on the device (in °C). Reading (/get
) this attribute is not possible.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,heat
,auto
. Reading (/get
) this attribute is not possible.local_temperature_calibration
: Offset to be used in the local_temperature. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"local_temperature_calibration": VALUE}.
The minimal value is-6
and the maximum value is6
with a step size of1
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.