Climax SD-8SCZBS
Model | SD-8SCZBS |
Vendor | Climax |
Description | Smoke detector |
Exposes | smoke, battery, battery_low, tamper, warning, linkquality |
Picture |
Exposes
Smoke (binary)
Indicates whether the device detected smoke.
Value can be found in the published state on the smoke
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
smoke is ON, if false
OFF.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Battery_low (binary)
Indicates if the battery of this device is almost empty.
Value can be found in the published state on the battery_low
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
battery_low is ON, if false
OFF.
Tamper (binary)
Indicates whether the device is tampered.
Value can be found in the published state on the tamper
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
tamper is ON, if false
OFF.
Warning (composite)
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"warning": {"mode": VALUE, "level": VALUE, "strobe_level": VALUE, "strobe": VALUE, "strobe_duty_cycle": VALUE, "duration": VALUE}}
mode
(enum): Mode of the warning (sound effect) allowed values:stop
,burglar
,fire
,emergency
,police_panic
,fire_panic
,emergency_panic
level
(enum): Sound level allowed values:low
,medium
,high
,very_high
strobe_level
(enum): Intensity of the strobe allowed values:low
,medium
,high
,very_high
strobe
(binary): Turn on/off the strobe (light) during warning allowed values:true
orfalse
strobe_duty_cycle
(numeric): Length of the flash cycle max value is 10duration
(numeric): Duration in seconds of the alarm unit is s
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.