Leviton RC-2000WH
Model | RC-2000WH |
Vendor | Leviton |
Description | Omnistat2 wireless thermostat |
Exposes | climate (occupied_heating_setpoint, local_temperature, system_mode, fan_mode, occupied_cooling_setpoint, local_temperature_calibration, pi_heating_demand), linkquality |
Picture |
Options
How to use device type specific configuration
-
thermostat_unit
: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius
,fahrenheit
-
legacy
: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must betrue
orfalse
Exposes
Climate
This climate device supports the following features: occupied_heating_setpoint
, local_temperature
, system_mode
, fan_mode
, occupied_cooling_setpoint
, local_temperature_calibration
, pi_heating_demand
.
occupied_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_heating_setpoint": VALUE}
whereVALUE
is the °C between10
and30
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_heating_setpoint": ""}
.occupied_cooling_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_cooling_setpoint": VALUE}
whereVALUE
is the °C between10
and30
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_cooling_setpoint": ""}
.pi_heating_demand
: Position of the valve (= demanded heat) where 0% is fully closed and 100% is fully open. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"pi_heating_demand": VALUE}
whereVALUE
is the % between0
and100
. Reading (/get
) this attribute is not possible.local_temperature
: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature": ""}
.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,auto
,heat
,cool
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"system_mode": ""}
.local_temperature_calibration
: Offset to be used in the local_temperature. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"local_temperature_calibration": VALUE}.
To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature": ""}
.The minimal value is-12.8
and the maximum value is12.7
with a step size of0.1
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.