QOTO QT-05M
Model | QT-05M |
Vendor | QOTO |
Description | Solar powered garden watering timer |
Exposes | water_flow, last_watering_duration, remaining_watering_time, valve_state, shutdown_timer, valve_state_auto_shutdown, battery, linkquality |
Picture |
Exposes
Water_flow (numeric)
Current water flow in %..
Value can be found in the published state on the water_flow
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Last_watering_duration (numeric)
Last watering duration in seconds..
Value can be found in the published state on the last_watering_duration
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is sec
.
Remaining_watering_time (numeric)
Remaning watering time (for auto shutdown). Updates every minute, and every 10s in the last minute..
Value can be found in the published state on the remaining_watering_time
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is sec
.
Valve_state (numeric)
Set valve to %..
Value can be found in the published state on the valve_state
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"valve_state": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Shutdown_timer (numeric)
Auto shutdown in seconds..
Value can be found in the published state on the shutdown_timer
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"shutdown_timer": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 14400
.
The unit of this value is sec
.
Valve_state_auto_shutdown (numeric)
Set valve to % with auto shutdown..
Value can be found in the published state on the valve_state_auto_shutdown
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"valve_state_auto_shutdown": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.