Xiaomi QBKG20LM

   
Model QBKG20LM
Vendor Xiaomi
Description Aqara smart wall switch T1 (with neutral, double rocker)
Exposes switch (state), power, energy, voltage, flip_indicator_light, power_outage_memory, led_disabled_night, device_temperature, action, operation_mode, linkquality
Picture Xiaomi QBKG20LM

OTA updates

This device supports OTA updates, for more information see OTA updates.

Options

How to use device type specific configuration

  • state_action: State actions will also be published as ‘action’ when true (default false). The value must be true or false

  • power_calibration: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.

  • power_precision: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • energy_calibration: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.

  • energy_precision: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • voltage_calibration: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number.

  • voltage_precision: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • device_temperature_calibration: Calibrates the device_temperature value (absolute offset), takes into effect on next report of device. The value must be a number.

Exposes

Switch (left endpoint)

The current state of this switch is in the published state under the state_left property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state_left": "ON"}, {"state_left": "OFF"} or {"state_left": "TOGGLE"}. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state_left": ""}.

Switch (right endpoint)

The current state of this switch is in the published state under the state_right property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state_right": "ON"}, {"state_right": "OFF"} or {"state_right": "TOGGLE"}. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state_right": ""}.

Power (numeric)

Instantaneous measured power. Value can be found in the published state on the power property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is W.

Energy (numeric)

Sum of consumed energy. Value can be found in the published state on the energy property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is kWh.

Voltage (numeric)

Measured electrical potential value. Value can be found in the published state on the voltage property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is V.

Flip_indicator_light (binary)

After turn on, the indicator light turns on while switch is off, and vice versa. Value can be found in the published state on the flip_indicator_light property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"flip_indicator_light": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"flip_indicator_light": NEW_VALUE}. If value equals ON flip_indicator_light is ON, if OFF OFF.

Power_outage_memory (binary)

Enable/disable the power outage memory, this recovers the on/off mode after power failure. Value can be found in the published state on the power_outage_memory property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"power_outage_memory": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"power_outage_memory": NEW_VALUE}. If value equals true power_outage_memory is ON, if false OFF.

Led_disabled_night (binary)

Enable/disable the LED at night. Value can be found in the published state on the led_disabled_night property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"led_disabled_night": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"led_disabled_night": NEW_VALUE}. If value equals true led_disabled_night is ON, if false OFF.

Device_temperature (numeric)

Temperature of the device. Value can be found in the published state on the device_temperature property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is °C.

Action (enum)

Triggered action (e.g. a button click). Value can be found in the published state on the action property. It’s not possible to read (/get) or write (/set) this value. The possible values are: single_left, double_left, single_right, double_right, single_both, double_both.

Operation_mode (enum, left endpoint)

Decoupled mode for left button. Value can be found in the published state on the operation_mode_left property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"operation_mode_left": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"operation_mode_left": NEW_VALUE}. The possible values are: control_relay, decoupled.

Operation_mode (enum, right endpoint)

Decoupled mode for right button. Value can be found in the published state on the operation_mode_right property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"operation_mode_right": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"operation_mode_right": NEW_VALUE}. The possible values are: control_relay, decoupled.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.