Description | Parkside smart watering timer |
Exposes | battery, switch (state), timer, time_left, frost_lock, reset_frost_lock, schedule_mode, schedule_periodic, schedule_weekday, schedule_slot_1, schedule_slot_2, schedule_slot_3, schedule_slot_4, schedule_slot_5, schedule_slot_6, linkquality |
Picture |
Exposes
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
It’s not possible to read (/get
) this value.
Timer (numeric)
Auto off after specific time for manual watering..
Value can be found in the published state on the timer
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"timer": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 599
.
The unit of this value is min
.
Time_left (numeric)
Remaining time until the watering turns off..
Value can be found in the published state on the time_left
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is min
.
Frost_lock (binary)
Indicates if the frost guard is currently active. If the temperature drops below 5° C, device activates frost guard and disables irrigation. You need to reset the frost guard to activate irrigation again. Note: There is no way to enable frost guard manually..
Value can be found in the published state on the frost_lock
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals ON
frost_lock is ON, if OFF
OFF.
Reset_frost_lock (enum)
Resets frost lock to make the device workable again..
Value will not be published in the state.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"reset_frost_lock": NEW_VALUE}
.
The possible values are: RESET
.
Schedule_mode (enum)
Scheduling mode that is currently in use..
Value can be found in the published state on the schedule_mode
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: OFF
, WEEKDAY
, PERIODIC
.
Schedule_periodic (numeric)
Watering by periodic interval: Irrigate every n days.
Value can be found in the published state on the schedule_periodic
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"schedule_periodic": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 7
.
The unit of this value is day
.
Schedule_weekday (composite)
Watering by weekday: Irrigate individually for each day..
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"schedule_weekday": {"monday": VALUE, "tuesday": VALUE, "wednesday": VALUE, "thursday": VALUE, "friday": VALUE, "saturday": VALUE, "sunday": VALUE}}
monday
(binary) allowed values:ON
orOFF
tuesday
(binary) allowed values:ON
orOFF
wednesday
(binary) allowed values:ON
orOFF
thursday
(binary) allowed values:ON
orOFF
friday
(binary) allowed values:ON
orOFF
saturday
(binary) allowed values:ON
orOFF
sunday
(binary) allowed values:ON
orOFF
Schedule_slot_1 (composite)
Watering time slot 1.
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"schedule_slot_1": {"state": VALUE, "start_hour": VALUE, "start_minute": VALUE, "timer": VALUE, "pause": VALUE, "iterations": VALUE}}
state
(binary): On/off state of the time slot allowed values:ON
orOFF
start_hour
(numeric): Starting time (hour) max value is 23, unit is hstart_minute
(numeric): Starting time (minute) max value is 59, unit is mintimer
(numeric): Auto off after specific time for scheduled watering. min value is 1, max value is 599, unit is minpause
(numeric): Pause after each iteration. max value is 599, unit is miniterations
(numeric): Number of watering iterations. Works only if there is a pause. min value is 1, max value is 9
Schedule_slot_2 (composite)
Watering time slot 2.
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"schedule_slot_2": {"state": VALUE, "start_hour": VALUE, "start_minute": VALUE, "timer": VALUE, "pause": VALUE, "iterations": VALUE}}
state
(binary): On/off state of the time slot allowed values:ON
orOFF
start_hour
(numeric): Starting time (hour) max value is 23, unit is hstart_minute
(numeric): Starting time (minute) max value is 59, unit is mintimer
(numeric): Auto off after specific time for scheduled watering. min value is 1, max value is 599, unit is minpause
(numeric): Pause after each iteration. max value is 599, unit is miniterations
(numeric): Number of watering iterations. Works only if there is a pause. min value is 1, max value is 9
Schedule_slot_3 (composite)
Watering time slot 3.
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"schedule_slot_3": {"state": VALUE, "start_hour": VALUE, "start_minute": VALUE, "timer": VALUE, "pause": VALUE, "iterations": VALUE}}
state
(binary): On/off state of the time slot allowed values:ON
orOFF
start_hour
(numeric): Starting time (hour) max value is 23, unit is hstart_minute
(numeric): Starting time (minute) max value is 59, unit is mintimer
(numeric): Auto off after specific time for scheduled watering. min value is 1, max value is 599, unit is minpause
(numeric): Pause after each iteration. max value is 599, unit is miniterations
(numeric): Number of watering iterations. Works only if there is a pause. min value is 1, max value is 9
Schedule_slot_4 (composite)
Watering time slot 4.
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"schedule_slot_4": {"state": VALUE, "start_hour": VALUE, "start_minute": VALUE, "timer": VALUE, "pause": VALUE, "iterations": VALUE}}
state
(binary): On/off state of the time slot allowed values:ON
orOFF
start_hour
(numeric): Starting time (hour) max value is 23, unit is hstart_minute
(numeric): Starting time (minute) max value is 59, unit is mintimer
(numeric): Auto off after specific time for scheduled watering. min value is 1, max value is 599, unit is minpause
(numeric): Pause after each iteration. max value is 599, unit is miniterations
(numeric): Number of watering iterations. Works only if there is a pause. min value is 1, max value is 9
Schedule_slot_5 (composite)
Watering time slot 5.
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"schedule_slot_5": {"state": VALUE, "start_hour": VALUE, "start_minute": VALUE, "timer": VALUE, "pause": VALUE, "iterations": VALUE}}
state
(binary): On/off state of the time slot allowed values:ON
orOFF
start_hour
(numeric): Starting time (hour) max value is 23, unit is hstart_minute
(numeric): Starting time (minute) max value is 59, unit is mintimer
(numeric): Auto off after specific time for scheduled watering. min value is 1, max value is 599, unit is minpause
(numeric): Pause after each iteration. max value is 599, unit is miniterations
(numeric): Number of watering iterations. Works only if there is a pause. min value is 1, max value is 9
Schedule_slot_6 (composite)
Watering time slot 6.
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"schedule_slot_6": {"state": VALUE, "start_hour": VALUE, "start_minute": VALUE, "timer": VALUE, "pause": VALUE, "iterations": VALUE}}
state
(binary): On/off state of the time slot allowed values:ON
orOFF
start_hour
(numeric): Starting time (hour) max value is 23, unit is hstart_minute
(numeric): Starting time (minute) max value is 59, unit is mintimer
(numeric): Auto off after specific time for scheduled watering. min value is 1, max value is 599, unit is minpause
(numeric): Pause after each iteration. max value is 599, unit is miniterations
(numeric): Number of watering iterations. Works only if there is a pause. min value is 1, max value is 9
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.