Meazon MEAZON_DINRAIL

   
Model MEAZON_DINRAIL
Vendor Meazon
Description DinRail 1-phase meter
Exposes switch (state), power, voltage, current, linkquality
Picture Meazon MEAZON_DINRAIL

Notes

Deprecated click event

By default this device exposes a deprecated click event. It’s recommended to use the action event instead.

To disable the click event, set legacy: false for this device in configuration.yaml. Example:

devices:
  '0x12345678':
    friendly_name: my_device
    legacy: false

Options

How to use device type specific configuration

  • legacy: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must be true or false

  • state_action: State actions will also be published as ‘action’ when true (default false). The value must be true or false

Exposes

Switch

The current state of this switch is in the published state under the state property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "ON"}, {"state": "OFF"} or {"state": "TOGGLE"}. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state": ""}.

Power (numeric)

Instantaneous measured power. Value can be found in the published state on the power property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is W.

Voltage (numeric)

Measured electrical potential value. Value can be found in the published state on the voltage property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is V.

Current (numeric)

Instantaneous measured electrical current. Value can be found in the published state on the current property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is A.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.