TuYa LCZ030
Model | LCZ030 |
Vendor | TuYa |
Description | Temperature & humidity & illuminance sensor with display |
Exposes | temperature, humidity, battery, illuminance, illuminance_lux, alarm_temperature_max, alarm_temperature_min, alarm_humidity_max, alarm_humidity_min, alarm_humidity, alarm_temperature, linkquality |
Picture |
Notes
Warning
For full functionality of this device you will need to pair it to a TuYa Gateway prior use.
Options
How to use device type specific configuration
-
illuminance_calibration
: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number. -
illuminance_lux_calibration
: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number. -
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Temperature (numeric)
Measured temperature value.
Value can be found in the published state on the temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity.
Value can be found in the published state on the humidity
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Illuminance (numeric)
Raw measured illuminance.
Value can be found in the published state on the illuminance
property.
It’s not possible to read (/get
) or write (/set
) this value.
Illuminance_lux (numeric)
Measured illuminance in lux.
Value can be found in the published state on the illuminance_lux
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is lx
.
Alarm_temperature_max (numeric)
Alarm temperature max.
Value can be found in the published state on the alarm_temperature_max
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"alarm_temperature_max": NEW_VALUE}
.
The minimal value is -20
and the maximum value is 80
.
The unit of this value is °C
.
Alarm_temperature_min (numeric)
Alarm temperature min.
Value can be found in the published state on the alarm_temperature_min
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"alarm_temperature_min": NEW_VALUE}
.
The minimal value is -20
and the maximum value is 80
.
The unit of this value is °C
.
Alarm_humidity_max (numeric)
Alarm humidity max.
Value can be found in the published state on the alarm_humidity_max
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"alarm_humidity_max": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Alarm_humidity_min (numeric)
Alarm humidity min.
Value can be found in the published state on the alarm_humidity_min
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"alarm_humidity_min": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Alarm_humidity (enum)
Alarm humidity status.
Value can be found in the published state on the alarm_humidity
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: below_min_humdity
, over_humidity
, off
.
Alarm_temperature (enum)
Alarm temperature status.
Value can be found in the published state on the alarm_temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: below_min_temperature
, over_temperature
, off
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.