Xiaomi JTYJ-GD-01LM/BW
Model | JTYJ-GD-01LM/BW |
Vendor | Xiaomi |
Description | MiJia Honeywell smoke detector |
Exposes | smoke, battery_low, tamper, battery, sensitivity, smoke_density, selftest, voltage, test, device_temperature, power_outage_count, linkquality |
Picture | |
White-label | Xiaomi YTC4020RT |
Notes
Pairing
Plug the device in and wait for around 5mins, while it performs its self-tests. A successful self-test is indicated by couple of beeps and a steady green led. Now the device is ready for pairing. To initiate pairing quickly press the button three times in a row.
Sensitivity
The sensitivity can be changed by publishing to zigbee2mqtt/FRIENDLY_NAME/set
{"sensitivity": "SENSITIVITY"}
where SENSITIVITY
is one of the following
values: low
, medium
, high
.
Self-test
A self-test can be trigged by publishing to zigbee2mqtt/FRIENDLY_NAME/set
{"selftest": ""}
.
If the selftest is executed successfully you will hear the device beep in 30 seconds.
Options
How to use device type specific configuration
device_temperature_calibration
: Calibrates the device_temperature value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Smoke (binary)
Indicates whether the device detected smoke.
Value can be found in the published state on the smoke
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
smoke is ON, if false
OFF.
Battery_low (binary)
Indicates if the battery of this device is almost empty.
Value can be found in the published state on the battery_low
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
battery_low is ON, if false
OFF.
Tamper (binary)
Indicates whether the device is tampered.
Value can be found in the published state on the tamper
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
tamper is ON, if false
OFF.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Sensitivity (enum)
Value can be found in the published state on the sensitivity
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"sensitivity": NEW_VALUE}
.
The possible values are: low
, medium
, high
.
Smoke_density (numeric)
Value can be found in the published state on the smoke_density
property.
It’s not possible to read (/get
) or write (/set
) this value.
Selftest (enum)
Value will not be published in the state.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"selftest": NEW_VALUE}
.
The possible values are: ``.
Voltage (numeric)
Voltage of the battery in millivolts.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is mV
.
Test (binary)
Test mode activated.
Value can be found in the published state on the test
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
test is ON, if false
OFF.
Device_temperature (numeric)
Temperature of the device.
Value can be found in the published state on the device_temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Power_outage_count (numeric)
Number of power outages.
Value can be found in the published state on the power_outage_count
property.
It’s not possible to read (/get
) or write (/set
) this value.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.