HEIMAN HS2IRC
Model | HS2IRC |
Vendor | HEIMAN |
Description | Smart IR Control |
Exposes | battery, linkquality |
Picture |
Notes
Device can learn up to 15 devices and up to 30 keycodes for each device.
Configuring
By publishing to zigbee2mqtt/FRIENDLY_NAME/set
various device attributes can be configured:
Create device
Request:
{
"create": {
"model_type": 55
}
}
- model_type: User-defined model ID. Used just for reference. Can be
1..255
.
Response:
{
"action": "create",
"action_result": "success",
"action_model_type": 55,
"action_id": 1
}
- action_result: (
success
/error
). Action result. - action_model_type: User-defined model ID.
1..255
- action_id: Internal device slot ID. Total IR transmitter can store up to 15 devices with ID
1..15
NOTE: You should call get_list
manually to refresh devices
topic.
Learn key
Request:
{
"learn": {
"id": 1,
"key_code": 31
}
}
- id: Internal device slot ID.
1..15
. - key_code: Keycode slot ID.
1..30
- Store/replace specific key in specified slot ID.>=31
- Create slot ID.
NOTE: You should store keys one-by-one if you specified key_code
by yourself.
Response:
{
"action": "learn",
"action_result": "success",
"action_key_code": 1,
"action_id": 1
}
- action_result: (
success
/error
). Action result. - action_key_code: Internal keycode slot ID, where key was stored.
1...30
- action_id: Internal device slot ID.
1..15
NOTE: You should call get_list
manually to refresh devices
topic after learning key.
Send stored key
Request:
{
"send_key": {
"id": 1,
"key_code": 1
}
}
- id: Internal device slot ID.
1..15
. - key_code: Keycode slot ID.
1..30
.
Get list of the stored devices and keys
Request:
{
"get_list": ""
}
Response:
{
"devices": [
{
"id": 1,
"key_codes": [
1,
],
"model_type": 55
}
]
}
Delete device or keycode
Request:
{
"delete":{
"id": 1,
"key_code": 31
}
}
- id:
1..15
- Delete specific device with ID.>=16
- Delete all devices. - key_code:
1..30
-Delete specific keycode.>=31
- Delete all keycodes for specified device ID.
Exposes
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.