Heimgard Technologies HC-IWDIM-1
Model | HC-IWDIM-1 |
Vendor | Heimgard Technologies |
Description | Dimmer |
Exposes | light (state, brightness), power, current, voltage, energy, linkquality |
Picture |
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
-
transition
: Controls the transition time (in seconds) of on/off, brightness, color temperature (if applicable) and color (if applicable) changes. Defaults to0
(no transition). The value must be a number with a minimum value of0
-
state_action
: State actions will also be published as ‘action’ when true (default false). The value must betrue
orfalse
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number. -
current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number. -
voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Light
This light supports the following features: state
, brightness
.
state
: To control the state publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"state": "ON"}
,{"state": "OFF"}
or{"state": "TOGGLE"}
. To read the state send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"state": ""}
.brightness
: To control the brightness publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"brightness": VALUE}
whereVALUE
is a number between0
and254
. To read the brightness send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"brightness": ""}
.
Power (numeric)
Instantaneous measured power.
Value can be found in the published state on the power
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is W
.
Current (numeric)
Instantaneous measured electrical current.
Value can be found in the published state on the current
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is A
.
Voltage (numeric)
Measured electrical potential value.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is V
.
Energy (numeric)
Sum of consumed energy.
Value can be found in the published state on the energy
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is kWh
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.