BTicino F20T60A
Model | F20T60A |
Vendor | BTicino |
Description | DIN power consumption module (same as Legrand 412015) |
Exposes | switch (state, state), power, device_mode, linkquality |
Picture |
Notes
Pairing
This device ONLY works on channel 11. Once configured on channel 11, put your network in join mode and the device (steady red light) will auto join it.
Force read power
power
: Asks the device for the current active power.
Example of MQTT message payload to ask for the active power. This should be sent to zigbee2mqtt/FRIENDLY_NAME/get
:
{
"power"
}
Power Alarm Configuration
power_alarm
: enables or disables the power alarm, and sets the value:DISABLE
(default) /integer
(in kWh)
Example of MQTT message payload to disable the power alarm. This should be sent to zigbee2mqtt/FRIENDLY_NAME/set
:
{
"power_alarm": "DISABLE"
}
Example of MQTT message payload to enable the power alarm at 3.3 kWh. This should be sent to zigbee2mqtt/FRIENDLY_NAME/set
:
{
"power_alarm": "3300"
}
When it reaches that value, the power_alarm_active
binary_sensor will change to true
.
Identify
Helps to identify the device using the LED.
identify['effect']
: only works for blink3 & fixed ineffect
. Values:blink3
fixed
blinkgreen
blinkblue
identify['color']
: only works for blink3 & fixed ineffect
. Values:default
red
green
blue
lightblue
yellow
pink
white
Example of MQTT message payload to Identify the device. This should be sent to zigbee2mqtt/FRIENDLY_NAME/set
:
{
"identify": {
"effect": "blink3",
"color": "white"
}
}
Options
How to use device type specific configuration
-
state_action
: State actions will also be published as ‘action’ when true (default false). The value must betrue
orfalse
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number. -
current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number. -
voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
Exposes
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
Power (numeric)
Instantaneous measured power.
Value can be found in the published state on the power
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power": ""}
.
It’s not possible to write (/set
) this value.
The unit of this value is W
.
Device_mode (enum)
switch: allow on/off, auto will use wired action via C1/C2 on contactor for example with HC/HP.
Value can be found in the published state on the device_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"device_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"device_mode": NEW_VALUE}
.
The possible values are: switch
, auto
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.