TuYa ERS-10TZBVK-AA
Model | ERS-10TZBVK-AA |
Vendor | TuYa |
Description | Smart knob |
Exposes | action, action_step_size, action_transition_time, action_rate, battery, operation_mode, linkquality |
Picture |
Notes
Pairing
To pair, press the reset button on the back until the green LED flashes.
Note: When you release the reset button, the green LED should keep flashing until the device is paired. If it only flashes a few times and then stops, your battery level is most likely too low (<3v) and you need to replace the battery.
The toggle
action switches on/off an unexpected zigbee device
The source of the problem is that manufactures of the knob and another device placed them into group 0 by default. To bypass it, you should manually create a group in Z2M with different ID (ID=1, for example) and add your knob inside. For more details take a look at the issue.
Device operation
Device can be set in two modes : COMMAND and EVENT (Current Mode is published on the operation_mode property). A triple click seems firmware dependend (no action shown) and will toggle between COMMAND and EVENT mode.
COMMAND
mode
User Action | action property |
---|---|
Rotate Left | Brightness_Step_Up |
Rotate Right | Brightness_Step_Down |
Single Click | Toggle |
HOLD more than 3s | Hue_Move |
UnHold button | Hue_Stop |
Push+Hold and Rotate Left | color_temperature_step_up |
Push+Hold and Rotate Left | color_temperature_step_down |
Action_Step_Size = %Numeric_Value (0_255) Action_Rate = Keeps “No value” all the time
EVENT
mode
User Action | action property |
---|---|
Rotate Left | rotate_left |
Rotate Left | rotate_right |
Single Click | single |
Double Click | double |
Hold | hold |
action_step_size, action_transition_time, action_rate are still present but show “no value”
Options
How to use device type specific configuration
simulated_brightness
: Simulate a brightness value. If this device provides a brightness_move_up or brightness_move_down action it is possible to specify the update interval and delta. The action_brightness_delta indicates the delta for each interval. Example:simulated_brightness: delta: 20 # delta per interval, default = 20 interval: 200 # interval in milliseconds, default = 200
Exposes
Action (enum)
Triggered action (e.g. a button click).
Value can be found in the published state on the action
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: toggle
, brightness_step_up
, brightness_step_down
, color_temperature_step_up
, color_temperature_step_down
, saturation_move
, hue_move
, hue_stop
, single
, double
, hold
, rotate_left
, rotate_right
.
Action_step_size (numeric)
Value can be found in the published state on the action_step_size
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
Action_transition_time (numeric)
Value can be found in the published state on the action_transition_time
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is s
.
Action_rate (numeric)
Value can be found in the published state on the action_rate
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Operation_mode (enum)
Operation mode: “command” - for group control, “event” - for clicks.
Value can be found in the published state on the operation_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"operation_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"operation_mode": NEW_VALUE}
.
The possible values are: command
, event
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.