Custom devices (DiY) EFEKTA_eFlower_Pro
Model | EFEKTA_eFlower_Pro |
Vendor | Custom devices (DiY) |
Description | Plant Wattering Sensor with e-ink display 2.13 |
Exposes | soil_moisture, battery, illuminance, temperature, humidity, linkquality |
Picture |
Options
How to use device type specific configuration
-
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number. -
illuminance_calibration
: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number. -
illuminance_lux_calibration
: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number. -
soil_moisture_precision
: Number of digits after decimal point for soil_moisture, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
soil_moisture_calibration
: Calibrates the soil_moisture value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Soil_moisture (numeric)
Measured soil moisture value.
Value can be found in the published state on the soil_moisture
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Illuminance (numeric)
Raw measured illuminance.
Value can be found in the published state on the illuminance
property.
It’s not possible to read (/get
) or write (/set
) this value.
Temperature (numeric)
Measured temperature value.
Value can be found in the published state on the temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity.
Value can be found in the published state on the humidity
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.