Custom devices (DiY) EFEKTA_PWS
Model | EFEKTA_PWS |
Vendor | Custom devices (DiY) |
Description | [Plant Wattering Sensor, CR2450, CR2477 batteries, temperature ] |
Exposes | soil_moisture, battery, temperature, report_delay, linkquality |
Picture |
Notes
Build guide
Instructions on how to build this device can be found here
Options
How to use device type specific configuration
-
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number. -
illuminance_calibration
: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number. -
illuminance_lux_calibration
: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number. -
soil_moisture_precision
: Number of digits after decimal point for soil_moisture, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
soil_moisture_calibration
: Calibrates the soil_moisture value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Soil_moisture (numeric)
Measured soil moisture value.
Value can be found in the published state on the soil_moisture
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Temperature (numeric)
Measured temperature value.
Value can be found in the published state on the temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Report_delay (numeric)
Adjust Report Delay. Setting the time in minutes, by default 15 minutes.
Value can be found in the published state on the report_delay
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"report_delay": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 240
.
The unit of this value is min
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.