ShinaSystem DMS-300ZB
Model | DMS-300ZB |
Vendor | ShinaSystem |
Description | SiHAS dual motion sensor |
Exposes | battery, voltage, occupancy_in, occupancy_out, occupancy_or, occupancy_and, occupancy_timeout, linkquality |
Picture |
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
no_occupancy_since
: Sends a message after the last time no occupancy (occupancy: false) was detected. When setting this for example to [10, 60] a{"no_occupancy_since": 10}
will be send after 10 seconds and a{"no_occupancy_since": 60}
after 60 seconds. The value must be a list of [object Object].
Exposes
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Voltage (numeric)
Voltage of the battery in millivolts.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is mV
.
Occupancy_in (binary)
Indicates whether “IN” Sensor of the device detected occupancy.
Value can be found in the published state on the occupancy_in
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
occupancy_in is ON, if false
OFF.
Occupancy_out (binary)
Indicates whether “OUT” Sensor of the device detected occupancy.
Value can be found in the published state on the occupancy_out
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
occupancy_out is ON, if false
OFF.
Occupancy_or (binary)
Indicates whether “IN or OUT” Sensor of the device detected occupancy.
Value can be found in the published state on the occupancy_or
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
occupancy_or is ON, if false
OFF.
Occupancy_and (binary)
Indicates whether “IN and OUT” Sensor of the device detected occupancy.
Value can be found in the published state on the occupancy_and
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals true
occupancy_and is ON, if false
OFF.
Occupancy_timeout (numeric)
Value can be found in the published state on the occupancy_timeout
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"occupancy_timeout": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"occupancy_timeout": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 3600
.
The unit of this value is second
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.