DIYRuZ DIYRuZ_Flower
| Model | DIYRuZ_Flower |
| Vendor | DIYRuZ |
| Description | Flower sensor |
| Exposes | soil_moisture, battery, illuminance, humidity, pressure, temperature, linkquality |
| Picture | ![]() |
Options
How to use device type specific configuration
-
temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3 -
temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3 -
humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number. -
illuminance_calibration: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number. -
illuminance_lux_calibration: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number. -
soil_moisture_precision: Number of digits after decimal point for soil_moisture, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3 -
soil_moisture_calibration: Calibrates the soil_moisture value (absolute offset), takes into effect on next report of device. The value must be a number. -
pressure_precision: Number of digits after decimal point for pressure, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3 -
pressure_calibration: Calibrates the pressure value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Soil_moisture (numeric)
Measured soil moisture value.
Value can be found in the published state on the soil_moisture property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is %.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery property.
It’s not possible to read (/get) or write (/set) this value.
The minimal value is 0 and the maximum value is 100.
The unit of this value is %.
Illuminance (numeric)
Raw measured illuminance.
Value can be found in the published state on the illuminance property.
It’s not possible to read (/get) or write (/set) this value.
Humidity (numeric)
Measured relative humidity.
Value can be found in the published state on the humidity property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is %.
Pressure (numeric)
The measured atmospheric pressure.
Value can be found in the published state on the pressure property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is hPa.
Temperature (numeric, ds endpoint)
Measured temperature value.
Value can be found in the published state on the temperature_ds property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is °C.
Temperature (numeric, bme endpoint)
Measured temperature value.
Value can be found in the published state on the temperature_bme property.
It’s not possible to read (/get) or write (/set) this value.
The unit of this value is °C.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality property.
It’s not possible to read (/get) or write (/set) this value.
The minimal value is 0 and the maximum value is 255.