MatSee Plus DAC2161C
Model | DAC2161C |
Vendor | MatSee Plus |
Description | Smart Zigbee energy meter 80A din rail |
Exposes | switch (state), energy, power, voltage, current, fault, threshold_1, threshold_1_protection, threshold_1_value, threshold_2, threshold_2_protection, threshold_2_value, clear_fault, meter_id, linkquality |
Picture |
Options
How to use device type specific configuration
-
energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
It’s not possible to read (/get
) this value.
Energy (numeric)
Sum of consumed energy.
Value can be found in the published state on the energy
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is kWh
.
Power (numeric)
Instantaneous measured power.
Value can be found in the published state on the power
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is W
.
Voltage (numeric)
Measured electrical potential value.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is V
.
Current (numeric)
Instantaneous measured electrical current.
Value can be found in the published state on the current
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is A
.
Fault (enum)
Fault status of the device (clear = nothing).
Value can be found in the published state on the fault
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: clear
, over_current_threshold
, over_power_threshold
, over_voltage threshold
, wrong_frequency_threshold
.
Threshold_1 (enum)
State of threshold_1.
Value can be found in the published state on the threshold_1
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: not_set
, over_current_threshold
, over_voltage_threshold
.
Threshold_1_protection (binary)
OFF - alarm only, ON - relay will be off when threshold reached.
Value can be found in the published state on the threshold_1_protection
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals ON
threshold_1_protection is ON, if OFF
OFF.
Threshold_1_value (numeric)
Can be in Volt or Ampere depending on threshold setting. Setup the value on the device.
Value can be found in the published state on the threshold_1_value
property.
It’s not possible to read (/get
) or write (/set
) this value.
Threshold_2 (enum)
State of threshold_2.
Value can be found in the published state on the threshold_2
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: not_set
, over_current_threshold
, over_voltage_threshold
.
Threshold_2_protection (binary)
OFF - alarm only, ON - relay will be off when threshold reached.
Value can be found in the published state on the threshold_2_protection
property.
It’s not possible to read (/get
) or write (/set
) this value.
If value equals ON
threshold_2_protection is ON, if OFF
OFF.
Threshold_2_value (numeric)
Setup value on the device.
Value can be found in the published state on the threshold_2_value
property.
It’s not possible to read (/get
) or write (/set
) this value.
Clear_fault (binary)
Turn ON to clear last the fault.
Value can be found in the published state on the clear_fault
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"clear_fault": NEW_VALUE}
.
If value equals ON
clear_fault is ON, if OFF
OFF.
Meter_id (text)
Meter ID (ID of device).
Value can be found in the published state on the meter_id
property.
It’s not possible to read (/get
) or write (/set
) this value.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.