TuYa D3-DPWK-TY
| Model | D3-DPWK-TY |
| Vendor | TuYa |
| Description | HVAC controller |
| Exposes | climate (current_heating_setpoint, local_temperature, system_mode, running_state), linkquality |
| Picture | ![]() |
Exposes
Climate
This climate device supports the following features: current_heating_setpoint, local_temperature, system_mode, running_state.
current_heating_setpoint: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"current_heating_setpoint": VALUE}whereVALUEis the °C between5and30. Reading (/get) this attribute is not possible.local_temperature: Current temperature measured on the device (in °C). Reading (/get) this attribute is not possible.system_mode: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"system_mode": VALUE}whereVALUEis one of:off,auto,heat. Reading (/get) this attribute is not possible.running_state: The current running state. Possible values are:idle,heat,cool. Reading (/get) this attribute is not possible.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality property.
It’s not possible to read (/get) or write (/set) this value.
The minimal value is 0 and the maximum value is 255.
The unit of this value is lqi.