Moes BHT-006GBZB
Model | BHT-006GBZB |
Vendor | Moes |
Description | Smart heating thermostat |
Exposes | lock (state), deadzone_temperature, max_temperature_limit, min_temperature_limit, climate (current_heating_setpoint, local_temperature, local_temperature_calibration, system_mode, running_state, preset), sensor, program, linkquality |
Picture |
Exposes
Lock
The current state of this lock is in the published state under the child_lock
property (value is LOCK
or UNLOCK
).
To control this lock publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"child_lock": "LOCK"}
or {"child_lock": "UNLOCK"}
.
It’s not possible to read (/get
) this value.
Deadzone_temperature (numeric)
The delta between local_temperature and current_heating_setpoint to trigger Heat.
Value can be found in the published state on the deadzone_temperature
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"deadzone_temperature": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 5
.
The unit of this value is °C
.
Max_temperature_limit (numeric)
Maximum temperature limit. Cuts the thermostat out regardless of air temperature if the external floor sensor exceeds this temperature. Only used by the thermostat when in AL sensor mode..
Value can be found in the published state on the max_temperature_limit
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_temperature_limit": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 35
.
The unit of this value is °C
.
Min_temperature_limit (numeric)
Minimum temperature limit for frost protection. Turns the thermostat on regardless of setpoint if the tempreature drops below this..
Value can be found in the published state on the min_temperature_limit
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"min_temperature_limit": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 5
.
The unit of this value is °C
.
Climate
This climate device supports the following features: current_heating_setpoint
, local_temperature
, local_temperature_calibration
, system_mode
, running_state
, preset
.
current_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"current_heating_setpoint": VALUE}
whereVALUE
is the °C between5
and35
. Reading (/get
) this attribute is not possible.local_temperature
: Current temperature measured on the device (in °C). Reading (/get
) this attribute is not possible.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,heat
. Reading (/get
) this attribute is not possible.preset
: Mode of this device (similar to system_mode). To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"preset": VALUE}
whereVALUE
is one of:hold
,program
. Reading (/get
) this attribute is not possible.running_state
: The current running state. Possible values are:idle
,heat
,cool
. Reading (/get
) this attribute is not possible.local_temperature_calibration
: Offset to be used in the local_temperature. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"local_temperature_calibration": VALUE}.
The minimal value is-30
and the maximum value is30
with a step size of0.1
.
Sensor (enum)
Select temperature sensor to use.
Value can be found in the published state on the sensor
property.
It’s not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"sensor": NEW_VALUE}
.
The possible values are: IN
, AL
, OU
.
Program (composite)
Time of day and setpoint to use when in program mode.
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"program": {"weekdays_p1_hour": VALUE, "weekdays_p1_minute": VALUE, "weekdays_p1_temperature": VALUE, "weekdays_p2_hour": VALUE, "weekdays_p2_minute": VALUE, "weekdays_p2_temperature": VALUE, "weekdays_p3_hour": VALUE, "weekdays_p3_minute": VALUE, "weekdays_p3_temperature": VALUE, "weekdays_p4_hour": VALUE, "weekdays_p4_minute": VALUE, "weekdays_p4_temperature": VALUE, "saturday_p1_hour": VALUE, "saturday_p1_minute": VALUE, "saturday_p1_temperature": VALUE, "saturday_p2_hour": VALUE, "saturday_p2_minute": VALUE, "saturday_p2_temperature": VALUE, "saturday_p3_hour": VALUE, "saturday_p3_minute": VALUE, "saturday_p3_temperature": VALUE, "saturday_p4_hour": VALUE, "saturday_p4_minute": VALUE, "saturday_p4_temperature": VALUE, "sunday_p1_hour": VALUE, "sunday_p1_minute": VALUE, "sunday_p1_temperature": VALUE, "sunday_p2_hour": VALUE, "sunday_p2_minute": VALUE, "sunday_p2_temperature": VALUE, "sunday_p3_hour": VALUE, "sunday_p3_minute": VALUE, "sunday_p3_temperature": VALUE, "sunday_p4_hour": VALUE, "sunday_p4_minute": VALUE, "sunday_p4_temperature": VALUE}}
weekdays_p1_hour
(numeric) max value is 23, unit is hweekdays_p1_minute
(numeric) max value is 59, unit is mweekdays_p1_temperature
(numeric) min value is 5, max value is 35, unit is °Cweekdays_p2_hour
(numeric) max value is 23, unit is hweekdays_p2_minute
(numeric) max value is 59, unit is mweekdays_p2_temperature
(numeric) min value is 5, max value is 35, unit is °Cweekdays_p3_hour
(numeric) max value is 23, unit is hweekdays_p3_minute
(numeric) max value is 59, unit is mweekdays_p3_temperature
(numeric) min value is 5, max value is 35, unit is °Cweekdays_p4_hour
(numeric) max value is 23, unit is hweekdays_p4_minute
(numeric) max value is 59, unit is mweekdays_p4_temperature
(numeric) min value is 5, max value is 35, unit is °Csaturday_p1_hour
(numeric) max value is 23, unit is hsaturday_p1_minute
(numeric) max value is 59, unit is msaturday_p1_temperature
(numeric) min value is 5, max value is 35, unit is °Csaturday_p2_hour
(numeric) max value is 23, unit is hsaturday_p2_minute
(numeric) max value is 59, unit is msaturday_p2_temperature
(numeric) min value is 5, max value is 35, unit is °Csaturday_p3_hour
(numeric) max value is 23, unit is hsaturday_p3_minute
(numeric) max value is 59, unit is msaturday_p3_temperature
(numeric) min value is 5, max value is 35, unit is °Csaturday_p4_hour
(numeric) max value is 23, unit is hsaturday_p4_minute
(numeric) max value is 59, unit is msaturday_p4_temperature
(numeric) min value is 5, max value is 35, unit is °Csunday_p1_hour
(numeric) max value is 23, unit is hsunday_p1_minute
(numeric) max value is 59, unit is msunday_p1_temperature
(numeric) min value is 5, max value is 35, unit is °Csunday_p2_hour
(numeric) max value is 23, unit is hsunday_p2_minute
(numeric) max value is 59, unit is msunday_p2_temperature
(numeric) min value is 5, max value is 35, unit is °Csunday_p3_hour
(numeric) max value is 23, unit is hsunday_p3_minute
(numeric) max value is 59, unit is msunday_p3_temperature
(numeric) min value is 5, max value is 35, unit is °Csunday_p4_hour
(numeric) max value is 23, unit is hsunday_p4_minute
(numeric) max value is 59, unit is msunday_p4_temperature
(numeric) min value is 5, max value is 35, unit is °C
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.