Namron 4512749-N¶
Model | 4512749-N |
Vendor | Namron |
Description | Thermostat outlet socket |
Exposes | temperature, power, current, voltage, switch (state), power_on_behavior, linkquality |
Picture |
Options¶
How to use device type specific configuration
-
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number. -
current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number. -
voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
state_action
: State actions will also be published as ‘action’ when true (default false). The value must betrue
orfalse
-
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes¶
Temperature (numeric)¶
Measured temperature value.
Value can be found in the published state on the temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Power (numeric)¶
Instantaneous measured power.
Value can be found in the published state on the power
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is W
.
Current (numeric)¶
Instantaneous measured electrical current.
Value can be found in the published state on the current
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is A
.
Voltage (numeric)¶
Measured electrical potential value.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is V
.
Switch¶
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
Power_on_behavior (enum)¶
Controls the behavior when the device is powered on after power loss.
Value can be found in the published state on the power_on_behavior
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_on_behavior": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_on_behavior": NEW_VALUE}
.
The possible values are: off
, previous
, on
.
Linkquality (numeric)¶
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.