Namron 4512721
Model | 4512721 |
Vendor | Namron |
Description | Zigbee 4 channel switch K8 (black) |
Exposes | battery, action, linkquality |
Picture |
Notes
Pairing
- Remove the remote from previous zigbee network if it has already been added to it, otherwise pairing will fail. Please refer to the part “Factory Reset”.
- From your zigbee controller or hub interface, choose to add device or accessory and enter Pairing mode as instructed by the controller.
- Press and hold down top two buttons (channel 1 ON and OFF) until LED indicator turns on.
- Immediately short press the top right button (channel 1 OFF) to search nearby network, indicator flashes every 1 second, 20 seconds timeout if there is no network. Indicator will then blink 5 times quickly for successful pairing.
Factory Reset
- Press and hold down top two buttons (channel 1 ON and OFF) until LED indicator turns on
- Immediately short press the top left button (channel 1 ON) 5 times continuously, indicator flashes 3 times quickly to indicate successful reset.
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
simulated_brightness
: Simulate a brightness value. If this device provides a brightness_move_up or brightness_move_down action it is possible to specify the update interval and delta. The action_brightness_delta indicates the delta for each interval. Example:simulated_brightness: delta: 20 # delta per interval, default = 20 interval: 200 # interval in milliseconds, default = 200
Exposes
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Action (enum)
Triggered action (e.g. a button click).
Value can be found in the published state on the action
property.
It’s not possible to read (/get
) or write (/set
) this value.
The possible values are: on_l1
, off_l1
, brightness_move_up_l1
, brightness_move_down_l1
, brightness_stop_l1
, on_l2
, off_l2
, brightness_move_up_l2
, brightness_move_down_l2
, brightness_stop_l2
, on_l3
, off_l3
, brightness_move_up_l3
, brightness_move_down_l3
, brightness_stop_l3
, on_l4
, off_l4
, brightness_move_up_l4
, brightness_move_down_l4
, brightness_stop_l4
.
Linkquality (numeric)
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.