Connecte 4500994

   
Model 4500994
Vendor Connecte
Description Smart thermostat
Exposes state, lock (state), switch (state), climate (current_heating_setpoint, local_temperature, local_temperature_calibration, system_mode, running_state), sensor, external_temperature, hysteresis, max_temperature_protection, linkquality
Picture Connecte 4500994

Exposes

State (binary)

On/off state of the switch. Value can be found in the published state on the state property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": NEW_VALUE}. If value equals ON state is ON, if OFF OFF.

Lock

The current state of this lock is in the published state under the child_lock property (value is LOCK or UNLOCK). To control this lock publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"child_lock": "LOCK"} or {"child_lock": "UNLOCK"}. It’s not possible to read (/get) this value.

Switch

The current state of this switch is in the published state under the window_detection property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"window_detection": "ON"}, {"window_detection": "OFF"} or {"window_detection": "TOGGLE"}. It’s not possible to read (/get) this value.

Switch

The current state of this switch is in the published state under the away_mode property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"away_mode": "ON"}, {"away_mode": "OFF"} or {"away_mode": "undefined"}. It’s not possible to read (/get) this value.

Climate

This climate device supports the following features: current_heating_setpoint, local_temperature, local_temperature_calibration, system_mode, running_state.

  • current_heating_setpoint: Temperature setpoint. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"current_heating_setpoint": VALUE} where VALUE is the °C between 5 and 35. Reading (/get) this attribute is not possible.
  • local_temperature: Current temperature measured on the device (in °C). Reading (/get) this attribute is not possible.
  • system_mode: Mode of this device. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"system_mode": VALUE} where VALUE is one of: heat, auto. Reading (/get) this attribute is not possible.
  • running_state: The current running state. Possible values are: idle, heat. Reading (/get) this attribute is not possible.
  • local_temperature_calibration: Offset to be used in the local_temperature. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"local_temperature_calibration": VALUE}.The minimal value is -9 and the maximum value is 9 with a step size of 1.

Sensor (enum)

Select temperature sensor to use. Value can be found in the published state on the sensor property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"sensor": NEW_VALUE}. The possible values are: internal, external, both.

External_temperature (numeric)

Current temperature measured on the external sensor (floor). Value can be found in the published state on the external_temperature property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is °C.

Hysteresis (numeric)

The difference between the temperature at which the thermostat switches off, and the temperature at which it switches on again.. Value can be found in the published state on the hysteresis property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"hysteresis": NEW_VALUE}. The minimal value is 1 and the maximum value is 9.

Max_temperature_protection (numeric)

Max guarding temperature. Value can be found in the published state on the max_temperature_protection property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"max_temperature_protection": NEW_VALUE}. The minimal value is 20 and the maximum value is 95. The unit of this value is °C.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.