Third Reality 3RSPE01044BZ

   
Model 3RSPE01044BZ
Vendor Third Reality
Description Zigbee / BLE smart plug with power
Exposes switch (state), power_on_behavior, ac_frequency, power, power_factor, energy, current, voltage, linkquality
Picture Third Reality 3RSPE01044BZ

OTA updates

This device supports OTA updates, for more information see OTA updates.

Options

How to use device type specific configuration

  • state_action: State actions will also be published as ‘action’ when true (default false). The value must be true or false

  • power_calibration: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.

  • power_precision: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • current_calibration: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number.

  • current_precision: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • voltage_calibration: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number.

  • voltage_precision: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • energy_precision: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • energy_calibration: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.

Exposes

Switch

The current state of this switch is in the published state under the state property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "ON"}, {"state": "OFF"} or {"state": "TOGGLE"}. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state": ""}.

Power_on_behavior (enum)

Controls the behavior when the device is powered on after power loss. Value can be found in the published state on the power_on_behavior property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"power_on_behavior": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"power_on_behavior": NEW_VALUE}. The possible values are: off, previous, on.

Ac_frequency (numeric)

Measured electrical AC frequency. Value can be found in the published state on the ac_frequency property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is Hz.

Power (numeric)

Instantaneous measured power. Value can be found in the published state on the power property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is W.

Power_factor (numeric)

Instantaneous measured power factor. Value can be found in the published state on the power_factor property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is %.

Energy (numeric)

Sum of consumed energy. Value can be found in the published state on the energy property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is kWh.

Current (numeric)

Instantaneous measured electrical current. Value can be found in the published state on the current property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is A.

Voltage (numeric)

Measured electrical potential value. Value can be found in the published state on the voltage property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is V.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.