Legrand 199182

   
Model 199182
Vendor Legrand
Description Wired switch without neutral
Exposes light (state, brightness), ballast_minimum_level, ballast_maximum_level, device_mode, led_in_dark, led_if_on, power_on_behavior, linkquality
Picture Legrand 199182

OTA updates

This device supports OTA updates, for more information see OTA updates.

Options

How to use device type specific configuration

  • transition: Controls the transition time (in seconds) of on/off, brightness, color temperature (if applicable) and color (if applicable) changes. Defaults to 0 (no transition). The value must be a number with a minimum value of 0

  • state_action: State actions will also be published as ‘action’ when true (default false). The value must be true or false

Exposes

Light

This light supports the following features: state, brightness.

  • state: To control the state publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "ON"}, {"state": "OFF"} or {"state": "TOGGLE"}. To read the state send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"state": ""}.
  • brightness: To control the brightness publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"brightness": VALUE} where VALUE is a number between 0 and 254. To read the brightness send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"brightness": ""}.

Ballast_minimum_level (numeric)

Specifies the minimum brightness value. Value can be found in the published state on the ballast_minimum_level property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"ballast_minimum_level": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"ballast_minimum_level": NEW_VALUE}. The minimal value is 1 and the maximum value is 254.

Ballast_maximum_level (numeric)

Specifies the maximum brightness value. Value can be found in the published state on the ballast_maximum_level property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"ballast_maximum_level": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"ballast_maximum_level": NEW_VALUE}. The minimal value is 1 and the maximum value is 254.

Device_mode (binary)

Allow the device to change brightness. Value can be found in the published state on the device_mode property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"device_mode": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"device_mode": NEW_VALUE}. If value equals dimmer_on device_mode is ON, if dimmer_off OFF.

Led_in_dark (binary)

Enables the LED when the light is turned off, allowing to see the switch in the dark. Value can be found in the published state on the led_in_dark property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"led_in_dark": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"led_in_dark": NEW_VALUE}. If value equals ON led_in_dark is ON, if OFF OFF.

Led_if_on (binary)

Enables the LED when the light is turned on. Value can be found in the published state on the led_if_on property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"led_if_on": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"led_if_on": NEW_VALUE}. If value equals ON led_if_on is ON, if OFF OFF.

Power_on_behavior (enum)

Controls the behavior when the device is powered on after power loss. Value can be found in the published state on the power_on_behavior property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"power_on_behavior": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"power_on_behavior": NEW_VALUE}. The possible values are: off, previous, on.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.